I.
DESCRIPTION.
This kit contains the cables and terminations required to operate five identical 1000 Watt BOP High Power mod-
els in parallel, effectively multiplying the output current capacity by five. Only identical models may be configured
to operate in parallel.
This kit can be used with all 1000W BOP models that have revision levels as shown in Table 1. Earlier models
that have been upgraded to permit multiple unit configurations must include the letter “A” following the revision
number. CAUTION: Failure to install the ground cables supplied can result in damage to the power supply.
Refer to the associated technical manual supplied with the 1000W BOP power supply for all instructions regard-
ing installation and operation of multiple units in parallel.
II.
SPECIFICATIONS
Table 3 lists the model parameters unique to a parallel combination of five identical 1000W BOP Power Supplies.
Table 4 lists the general specifications for the parallel combinations listed in Table 3. For specifications not listed
in Table 3, refer to the General Specifications provided in the associated technical manual supplied with each
1000W BOP power supply.
TABLE 1. REVISION LEVELS APPLICABLE TO THIS KIT
MG Model
Revision
Revisions for previously Upgraded
Units (Must include “A”)
GL Model
Revision
BOP 6-125MG
All
All
BOP 10-75MG
5 or higher
3A or 4A
BOP 20-50MG
8 or higher
5A, 6A or 7A
BOP 20-50GL
All
BOP 25-40MG
All
All
BOP 36-28MG
11 or higher
8A, 9A or 10A
BOP 50-20MG
7 or higher
5A or 6A
BOP 50-20GL
All
BOP 72-14MG
7 or higher
6A
BOP 100-10MG
6 or higher
2A or 4A
TABLE 2. EQUIPMENT SUPPLIED
Item
Quantity
Purpose
Kepco Part
Number
Common power cable, **
(1.5 ft.)
1
Connects the COMMON terminal Master to the COMMON terminal of Slave
#1.
118-1129
Common power cable, **
(3 ft.)
1
Connects the COMMON terminal Master to the COMMON terminal of Slave
#2.
118-1153
Common power cable, **
(4.5 ft.)
1
Connects the COMMON terminal Master to the COMMON terminal of Slave
#3.
118-1155
Common power cable, **
(6 ft.)
1
Connects the COMMON terminal Master to the COMMON terminal of Slave
#4.
118-1157
Output Power cable,
(1.5 ft.)
1
Connects the OUTPUT terminal of Master to the OUTPUT terminal of Slave
#1.
118-1112
Output Power cable,
(3 ft.)
1
Connects the OUTPUT terminal of Master to the OUTPUT terminal of Slave
#2.
118-1152
Output Power cable,
(4.5 ft.)
1
Connects the OUTPUT terminal of Master to the OUTPUT terminal of Slave
#3.
118-1154
** For GL units: Unclamp and remove ferrite from cable before installation.
!