KEPCO JBW 75W Series User Manual
75w series, Kepco, 75 watt single output switching power supplies

©2010, KEPCO, INC
1
Data subject to change without notice
228-1551 REV 2
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
http://www.kepcopower.com email: [email protected]
O P E R A T O R M A N U A L
KEPCO
An ISO 9001 Company.
JBW
75W SERIES
75 WATT SINGLE OUTPUT
SWITCHING POWER SUPPLIES
I — INTRODUCTION
SCOPE OF MANUAL. This instruction manual covers
the installation and operation of the Kepco JBW 75W
Series of RoHS (Reduction of Hazardous Substances)
compliant Switching Power Supplies.
DESCRIPTION. The Kepco JBW 75W Series consists of
four models of switching power supplies, each with a single
output as shown in Table 1. Units may be operated with a
nominal 100 to 120V a-c and 220 to 240V a-c (input voltage
range 85 to 265 Va-c), 50-60 Hz (input frequency range 47-
440Hz.) They will also operate on 120V to 370V d-c input.
The JBW 75W Series employs a light weight ferrite core.
Regulation is provided by pulse width modulation. Power
Factor Correction (PFC) is provided by a boost converter
operating at 80kHz. A FET power stage, operating as a for-
ward converter with a fixed switching frequency of 130kHz
provides a smooth isolated d-c output. A thermistor circuit
prevents excessive turn-on current surge. Overvoltage pro-
tection is provided. Current limiting with automatic recovery
from short circuit is featured. Units are manufactured on an
open frame PC board.
Table 1 contains specifications and operating limits of indi-
vidual JBW 75W Series models. Section II (following) con-
tains specifications and operating limits common to all JBW
75W Series Models
II — SPECIFICATIONS
The following specifications are at nominal input voltages
and 25°C and apply to all models unless otherwise speci-
fied.
INPUT CHARACTERISTICS:
INPUT VOLTAGE: (0 to 100% load, -10 to 60°C)
Nominal 100-120V a-c, 220-240V a-c
Range: 85-265V a-c, 110 -370V d-c
NOTE: The power supply may shut down if operated
below the input voltage range or if the input voltage
increases slowly at start up (> 1 second). To reset the
power supply, unplug the unit, wait one minute and
reapply input power.
INPUT SOURCE FREQUENCY:
Nominal 50/60 Hz;
Range 47-66 Hz (Above 66Hz to 440 Hz the leakage
current may exceed the VDE safety specification limit.)
INPUT CURRENT: (100% load at 25°C with nominal out-
put voltage):
100V a-c input:
1.0A typ., 1.6A max.
240V a-c input:
0.45A typ., 0.8A max.
INPUT PROTECTION AND SOFT START: A thermis-
tor circuit reduces start-up surge. Units are protected
against shorts by an input fuse. Fuse value 3.15A,
250V.
INPUT SURGE: Cold start:
100V a-c input, 100% load: 15A typ., 30.0A max.
240V a-c input, 100% load: 30A typ., 60.0A max.
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, JBW 75W SERIES
MODEL
JBW 5-15K
JBW 12-6.3K
JBW 15-5K
JBW 24-3.2K
OUTPUT VOLTS, d-c
5V ±0.25V
12V ±0.6V
15V ±0.75V
24V ±1.2V
ADJUSTMENT RANGE
4.5-5.5V
10.8-13.2V
13.5-16.5V
21.6-26.4V
CURRENT/POWER RATINGS
15.0A/75W
6.3A/75.6W
5.0A/75W
3.2A(1)/76.8W
OVERCURRENT (AMPS)
15.8 min.
6.6 min.
5.2 min.
4.4 min
OVP RANGE (VOLTS)
5.75-6.9
13.8-16.8
17.2-21.0
27.6-33.6
EFFICIENCY (typ.)
100 Va-c
75%
78%
79%
82%
240 Va-c
79%
81%
81%
84%
ACCEPTABLE EXTERNAL OUTPUT CAPACITOR
µFmax., (fixed load resistance)
30,000
30,000
30,000
30,000
RIPPLE AND
NOISE
(2)
(mV p-p)
ripple (typ)
80
120
120
120
ripple (typ) (-10 to 0
°C)
140
160
160
160
spike noise (typ)
120
150
150
150
spike noise (typ)
(-10 to 0
°C)
160
180
180
180
(1)
4.2A peak, t
≤
10 seconds., not to exceed 3.2A rms, output power
≤
75W.
(2)
0 to 100% load, 0 to 60 °C, tested with 100µF electrolytic and 0.1µF film capacitors across the measuring points, connected to the
power supply via 5.9 in (150mm) wires; oscilloscope bandwidth
≤
20MHz.
Document Outline
- I — INTRODUCTION
- Scope of Manual.
- Description.
- II — SPECIFICATIONS
- TABLE 1. Output Ratings And Specifications, JBW 75W Series
- Input Characteristics:
- Output Characteristics:
- Environmental Characteristics
- General Characteristics
- FIGURE 1. Output Power Vs. Temperature
- III — INSTALLATION
- Mounting Power Supply.
- Insulation.
- Ventilation.
- Connections.
- IV — OPERATION
- Protection Diode:
- FIGURE 2. Mounting Direction
- FIGURE 3. Ventilation and Insulation Requirements
- FIGURE 4. JBW 75W Mechanical Outline Diagram
- FIGURE 5. Input/Output connections