beautypg.com

Parking lights flash rate (normal operation), P. 14 user guide – Autostart AS-6250V User Manual

Page 14

background image

P. 14

User Guide

Parking Lights Flash Rate (Normal Operation)

Flashes

Description

1

• Doors locked, Alarm and starter kill armed.

• Run time has expired.

TRUNK

button pressed.

• Start signal received by the module.

• Cold weather mode cancelled.

2

• Remote start attempt cancelled by remote.

• Doors unlocked, starter kill disarmed.

• Exiting ignition valet

• Power ON to OFF(Automatic

transmission)

• Exiting remote valet

• Power-up reset.

• Board set from manual to automatic;

power ON

2 slow flashes then

8 quick flashes

• Reset from Manual to Automatic

3

• Entering ignition valet

• Entering or exiting Ready Mode

• Entering remote valet.

• Entering extended run time

4

• +12 V detected on the brake input wire

either while cranking or during run time.

• Entering multi-speed tach programming.

• Board set from automatic to manual; power

ON

• Power ON to OFF ( manual transmission)

5 Fast

• Tach signal programmed.

• New transmitter programmed.

6

• A remote start was attempted while a tach-before-crank signal was detected before cranking.

8

• Unit reset

10

• A ground (-) signal was detected on the hood pin input wire.

When pressing START

15 quick flashes

• The parking brake is connected to ground (automatic transmission)

1 – pause – 2

• There was a remote start attempt while the vehicle was in valet mode.

• Failed start: vehicle’s low battery voltage.

…followed by 1 flash

• Exiting cold weather mode

ON SOLID for 3

seconds….

…followed by 3 flashes

• Entering cold weather mode

ON continuously

Idle mode: Idle mode is engaged

Run time: The vehicle has been remote started and is in run time.

ON 2 seconds

• The hood has been opened and a ground (-) signal has been detected on the hood pin input

wire.

ON 4 seconds

• Locking or unlocking a door (with Door pulses configured to 4 sec.)

ON 20 seconds

• The hood pin has been flashed and you now have access to the programming options.

Constant flashes

up to 60 sec.

• In Siren or Horn Mode: Alarm condition generated by an intrusion, or when the System is

powered up.