Appendix, 1 specifications – Detcon FP-624D User Manual
Page 43
Model FP-624D
FP-624D Instruction Manual
Rev. 1.2
Page 39 of 42
9. Appendix
9.1 Specifications
Sensor Type:
Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
True plug-in replaceable type
Sensor Life:
3-5 years typical
Measuring Ranges:
0-100% LEL
Accuracy/ Repeatability:
± 3% LEL in 0-50% LEL range, ± 5% LEL in 51-100% LEL range
Response Time:
T50 < 10 seconds, T90 < 30 seconds
Performance Testing:
Complies with CSA C22.2 No. 152-M1984, ANSI/ISA S12.13
Electrical Classification:
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D
Approvals:
C
CSA
US
(To maintain the CSA certification, it must be calibrated on methane)
Applicable Standards
CSA C22.2 No. 30-M1986
CSA C22.2 No. 142-M1987
CSA C22.2 No. 152-M1984
UL Std. No. 916
UL Std. No.1203
ANSI/ISA S12.13
Warranty:
Electronics – 2 years
Sensor – 2 years
Environmental Specifications
Operating Temperature:
-40°C to +75°C
Storage Temperature:
-40°C to +75°C
Operating Humidity:
0-100% RH (Non-condensing)
Operating Pressure:
Ambient ± 10%
Electrical Specifications
Input Voltage:
12-28 VDC
Power Consumption:
Normal operation = 68mA (<1.7 watt); Maximum = 87mA (2 watts)
RFI/EMI Protection:
RFI Complies with ISA 92.0.01
Analog Output:
Linear 4-20mA DC current