Quad-4 dual hall effect pickup module, Installation and technical data guide, Rev 07/09 – AW Gear Meters Quad-4 User Manual
Page 2: Technical data

Quad-4 Dual Hall Effect Pickup Module
Installation and Technical Data Guide
AW Flow Meters - Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: [email protected] www.awcompany.com
Rev 07/09
Sinking Output Circuit
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog
Switch
Sourcing Output Circuit - Default from Factory
~40 Ohm
SUPPLY
OUTPUT
GROUND
Analog
Switch
• Output selection jumper off: remove shorting block from
JP1 & JP2
• User may need to add external components to interface
to displays or other instruments
• User must limit output voltage to Supply -1V
• Max current sinking capability: 50mA
• Output selection jumper on: place shorting block across
JP1 & JP2
• Signal output square wave :
Vhigh = Supply -1V @ no output load
Vlow = 0.1V
• Max sourced output voltage: Supply -0.5V
• Max current sourcing capabilities: 50mA
Supply Voltage:
+10 to 27 Volt DC
Supply Current:
75 mA @ 24 VDC
Duty Signal:
50% ± 15%
Minimum Signal:
0.5 Hz
Maximum Signal:
1,000 Hz
Frequency Output:
Flow dependent, up to 2,000 Hz
Driving Capacity:
50 mA Max resistive load
Output Impedance:
~ 40 Ohm - analog switch and self-resetting fuse
Temperature Range:
-40° F to 185° F (-40° C to 85° C)
Technical Data: