Backing up mapped alarms, Restoring mapped alarms, Backing up mapped alarms restoring mapped alarms – Avigilon Lenel OnGuard to ACC Alarm Gateway Integration User Manual
Page 9

Avigilon Control Center 5 System Integration Guide with Lenel OnGuard
6
c.
Enter the username and password you created earlier in the Avigilon
Control Center Client software. For more information, see Adding an
Integration User in Avigilon on page 3.
d.
Click OK.
Once the Gateway is linked to the Avigilon system, alarms created in the
Avigilon Control Center are auto-synchronized.
4.
Select an OnGuard device and a corresponding OnGuard event, then select an
Avigilon alarm to map to and click Add New Mapping.
The new alarm mapping is added to the Mapped Alarms list. Repeat this step
until all the mappings you need are added.
You can map multiple OnGuard devices and events to one Avigilon alarm, but
each OnGuard device and event can only be mapped once.
5.
Click Save.
6.
When you are ready, click Update Service. The Gateway service reboots and
the new mappings are put into effect.
Backing Up Mapped Alarms
After you finish mapping all the alarms in the OnGuard to ACC Alarm Gateway, you can
choose to back up a copy of the mappings.
1.
Navigate to
C:\Program Files\Avigilon\OnGuard to ACC Alarm Gateway\
.
NOTE: The filepath may be different depending on how your system is configured.
2.
Copy and paste the
AlarmConfig.xml
file to a back up location.
Restoring Mapped alarms
When you have a backup copy of the mapped alarms, you can restore the integration to
use the back up copy any time.
1.
Locate your backup copy of the
AlarmConfig.xml
file.
2.
Copy and paste the backup
AlarmConfig.xml
file into the application folder. The
filepath may look like this:
C:\Program Files\Avigilon\OnGuard to ACC Alarm Gateway\
Allow Windows to overwrite the copy that is currently in the folder.
3.
Open the configuration application and click Update Service.