Figure 14- Checking the oil

Changing/ Adding Oil

Change the oil according to the maintenance schedule in figure 13. Change the oil when the

engine is warm. This will allow for complete drainage. Change oil more often if operating under

heavy load or high ambient temperatures. It is also necessary to drain the oil from the crankcase if

it has become contaminated with water or dirt.
The oil capacity of the engine in this generator is 20 fluid oz

.

Add oil when the oil level is low.

Drain the oil from the generator according to the following steps:

1. Place a container underneath the engine to catch oil as it drains.

2. Using a 10 mm hex wrench, unscrew the oil drain plug (see figure 15). Allow all the oil to

drain from the engine.

3. Reinstall the oil drain plug and tighten with a 10 mm hex wrench.

To fill the crankcase with oil, follow these steps:

1. Make sure the generator is on a level surface. Tilting the generator to assist in filling will

cause oil to flow into engine areas and will cause damage. Keep generator level!

2. Remove the oil filler/dipstick cap from the engine as shown in figure 14 above.

3. Using a funnel, add the appropriate type and amount of oil into the crankcase. The

crankcase is full when the oil level has reached the second thread from the lip of the

opening (see figure 16).

4. Check for oil leaks. Reinstall oil filler cap before starting engine.

Figure 15- Draining oil Figure 16- Adding oil

NOTE: Never dispose of used motor oil in the trash or down a drain. Please call your local

recycling center or auto garage to arrange oil disposal.

21