WEN 56405 Power Pro 4050 Watt User Manual
Page 21
![background image](/manuals/366019/21/background.png)
If these specifications are not available, you may estimate the Watts required by your device using
the chart in figure 10.
When the running wattage requirement of each electrical device has been determined, add these
numbers to find the total running wattage needed. If this number exceeds the running wattage of
the generator, DO NOT connect all these devices. Select a combination of electrical devices,
which has a total running wattage lower than or equal to the running wattage of the generator.
CAUTION: The generator can run at its surge wattage capacity for only a short time.
Connect electrical devices requiring a rated (running) wattage equal to or less than the
running wattage of the generator. Never connect devices requiring a running wattage equal
to the starting wattage of the generator. This can trip the circuit protectors (circuit
breakers).
tool or appliance
rated (running) Watts
additional starting Watts
electric water heater (40 gal)
4000
0
hot plate
2500
0
saw- radial arm
2000
2000
electric stove (each element)
1500-2800
0
saw- circular
1500
1500
air compressor (1 HP)
1500
3000
window air conditioner
1200
1800
saw- miter
1200
1200
microwave
1000
0
well water pump
1000
1000
reciprocating saw
960
1040
sump pump
800
1200
refrigerator freezer
800
1200
furnace blower
800
1300
computer
800
0
electric drill
600
900
television
500
0
deep freezer
500
500
garage door opener
480
0
stereo
400
0
box fan
300
600
clock radio
300
0
security system
180
0
DVD player/ VCR
100
0
common light bulb
75
0
NOTE: The above wattage figures are estimates. Try to check the wattage listed on your electrical
device before consulting this chart.
Figure 10- Estimated wattage requirements of common electrical devices.
Once you have determined what electrical devices you will be powering with the generator,
connect these devices according to the following procedure:
17