Van Air Systems EDV-115-PA User Manual
Terminator, Model edv-115-pa, Installation, operation & maintenance instructions

PAGE 1
JAN 2011
P/N 432-10045
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
TERMINATOR
ELECTRONIC DRAIN VALVE
Model EDV-115-PA
(1/2" VALVE, LARGE ORIFICE)
PRODUCT PURPOSE & FUNCTION:
Van Air's model EDV-115-PA series drain valve is designed to remove accumulated fl uids from compressed air & gas process-
ing equipment. With variable open time (1-60 seconds) and valve closed time (1-60 minutes), users can easily adjust the valve to drain
the required amount of accumulated fl uids. Power on and valve open status lights, as well as a built-in override/test function, give quick
verifi cation of valve operation.
TM
EDV
-115-P
A
TM
Lake Cit
y, P
A 16423 USA
Ph: (800) 840-9906
ww
w.vanairsy
stems
.com
POWER
ON
CLOSED TIME
MINUTES
10
60
50
40
30
20
TEST
VA
LVE
OPEN
OPEN TIME
SEC
ONDS
10
60
50
40
30
20
1
EDV-115-PA
TM
Lake City, PA 16423 USA
Ph: (800) 840-9906
www.vanairsystems.com
CLOSED TIME
MINUTES
TEST
VALVE
OPEN
OPEN TIME
SECONDS
10
60
50
40
30
20
1
POWER
ON
10
60
50
40
30
20
Van Air
Part No
39-10510
Valve In/Out
Port Size
1/2"NPT
Orifi ce
Size
7/16"
Ambient
Temp Range
(°F/°C)
32-150/0-66
Electrical
V/PH/HZ
115-1-50/60
C
v
2.75
Working
Pressure Range
(psig/bar)
3-300/.2-20.7
Maximum
Fluid Temp
(°F/°C)
210/99
Approx
Weight
(lbs/Kg)
1.6/.7
2-1/4"
2"
3-1/16"
3-1/2"
1-15/16"
3-11/16"
Amps
.09
FIGURE 1 SPECIFICATIONS
2-1/4"
4-13/16"
5-7/16"
EDV-115-PA
• READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS DRAIN VALVE.
• DO NOT OPERATE LEAKING OR DAMAGED VALVES. REMOVE THEM FROM SERVICE IMMEDIATELY.
• DO NOT OPERATE VALVE ABOVE MAXIMUM OPERATING PRESSURE AND/OR MAXIMUM TEMPERATURE.
• MAKE SURE NEMA RATING OF VALVE IS COMPATIBLE WITH THE INSTALLATION ENVIRONMENT. FAILURE TO DO
SO MAY RESULT IN SERIOUS PERSONAL INJURY AND/OR DAMAGE TO THE UNIT.
• WHEN INSTALLING THIS UNIT, COMPLY WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE
FEDERAL, STATE AND LOCAL CODES.
• DRAIN SOLUTION MAY CONTAIN LUBRICANTS AND/OR HAZARDOUS MATERIALS. BE SURE TO COMPLY WITH
ALL APPLICABLE REGULATIONS CONCERNING THEIR DISPOSAL.
• NOT FOR USE ON SINGLE TOWER (DELIQUESCENT) DRYERS OR WITH CORROSIVE LIQUIDS.
WARNING
2950 Mechanic Street
Lake City, PA 16423 USA
Phone: 800/840-9906
Fax: 814/774-3482