PAGE 2

NEVER REMOVE OR REPLACE ANY PART ON EDV WHILE

IT IS PRESSURIZED. CLOSE INTEGRAL BALL VALVE

AND DEPRESSURIZE DRAIN LINE USING EDV TEST

INSTALLATION

Relieve and lock out all pressure from drain line.

Clean existing drain line of any pipe scale, weld spatter and

accumulated debris.

1.

2.

To verify valve operation, or to manually discharge fluid,

turn the "CLOSED TIME" knob counter clockwise until it stops in

the area labeled "TEST". The valve will open for the set "OPEN

TIME". After the valve closes, it will automatically repeat the test in

2 seconds unless the "CLOSED TIME" knob is reset to its regular

position.

TEST FUNCTION

Install a tee in the drain line.

(Reference Figure 2).

From the vertical tee outlet, install a manual drain valve to allow

the system to be drained during EDV servicing.

On the horizontal tee outlet, install the EDV drain valve.

Reference flow direction arrows on side of valve body.

3.

4.

5.

6.

7.

8.

9.

WARNING

UNIT TO BE DRAINED

TO DRAIN

TO DRAIN

MANUAL

DRAIN

BALL VALVE

TEE

FIGURE 2 RECOMMENDED INSTALLATION

CAUTION

IF THE EDV IS INSTALLED BACKWARDS, IT WILL NOT

WORK.

Set the valve open time & valve closed time control knobs

to conform to the desired draining schedule. Note that the

"VALVE OPEN" light is illuminated whenever the valve is open.

TIMER ADJUSTMENT

The integral strainer must be cleaned periodically to

ensure proper valve performance. The time between cleanings

will vary depending operating conditions. Remove cap to access

screen for cleaning.

(Reference Figure 2).

REQUIRED MAINTENANCE

TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION
Check electrical connections. Make sure that the drain valve is not installed

on a switched power supply line.

Replace timer assembly.

EDV drain valve has a 230 PSIG maximum working pressure.

Clean or replace valve.

Verify proper flow direction.

Replace timer assembly.

Replace valve.

Power to valve turned off or

interrupted.

Printed circuit board malfunction.

Excessive drain line pressure.

Valve plugged with debris.

Valve installed backwards.

Printed circuit board malfunction.

Valve malfunction.

Valve not operating

("POWER ON" light

is off)

Valve not operating

("POWER ON" light

is on)

REPLACEMENT

TIMER
VALVE
POWER CORD

EDV-115
39-10511
291-00017
500-00002

REPLACEMENT PARTS

2950 Mechanic Street

Lake City, PA 16423 USA

Phone: 800/840-9906

Fax: 814/774-3482

www.vanairsystems.com

Close the manual and integral ball valves.

Adjust timer knobs to desired settings

(Reference Timer

Adjustment Section).

Wire or plug the valve into the appropriate grounded power

supply. The "POWER ON" light should now be illuminated.

Open the integral ball valve. The EDV is now in service.

CAP

SCREEN

EDV

EDV-230
39-10512
291-00018
500-00003

EDV-12DC
39-10513
291-00019
500-00002