INSTALLING CK-1 & CK-1-2
Remove filter heads from filter bowls.
Apply grease to o-ring and place it on the
recess around the inlet/outlet area of one
filter head.
Place (1) standoff in each thru-hole.
Place (1) screw through each thru-hole on
the other side of the filter head and thread
into each standoff until snug.
Join the other head by holding each head
together with the standoffs in each thru-
hole between the heads as shown in Fig-
ure 1.(NOTE: Be sure that the heads are
connected in the correct flow direction.)
Place (1) screw through each thru-hole on
the other side of the second filter head and
thread into each standoff until snug.
Gradually tighten each screw down in a
alternating crisscross pattern to ensure an
even seal between the filter heads.
Follow Installation instructions on page 3
of the F200 Series Filter Housing instruc-
tion manual that is provided with each filter.
(NOTE: Read all instructions carefully be-
fore installing filters.)
1.
2.
3.
4.
5.
6.
7.
8.
INSTALLING CK-2 & CK-2-2
Remove filter heads from filter bowls.
Place each tie rod through the thru-holes of
one of the filter heads.
Place (1) washer on ends of the tie rods on
far side of the filter head.
Thread (1) nut onto each tie rod over each
washer.
Apply grease to o-ring and place it in the
recess around the inlet/outlet area of one
filter head.
Join the other head (with o-ring between
them) by feeding the tie rods through each
thru-hole until each filter head is together
as shown in Figure 1. (NOTE: Be sure that
the heads are connected in the correct
flow direction.)
Place (1) washer on other end of the tie
rods on outer side of the filter head.
Thread (1) nut onto each tie rod over each
washer.
Gradually tighten each screw down in a
alternating crisscross pattern to ensure an
even seal between the filter heads.
Follow Installation instructions on page 3
of the F200 Series Filter Housing instruc-
tion manual that is provided with each filter
(NOTE: Read all instructions carefully be-
fore installing filters.)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
INSTALLING CK-3-2
Remove filter heads from filter bowls.
Remove each blanking plates from the
filter heads.
Apply grease to o-ring and place it in the
recess around the inlet/outlet area of one
filter head.
Place (1) standoff in each thru-hole.
Place (1) screw through each thru-hole
inside the filter head and thread into each
standoff until snug.
Join the other head by holding each head
together with the standoffs in each thru-
hole between the filter heads as shown in
Figure 1. (NOTE: Be sure that the heads
are connected in the correct flow direc-
tion.)
Place (1) screw through each thru-hole
inside the second filter head and thread
into each standoff until snug.
Gradually tighten each screw down in a
alternating crisscross pattern to ensure an
even seal between the filter heads.
Follow Installation instructions on page 3
of the F200 Series Filter Housing instruc-
tion manual that is provided with each filter
(NOTE: Read all instructions carefully be-
fore installing filters.)
1.
2.
3.
4.
5.
6.
7.
8.
9.
FIGURE 1A CK-1 & CK-1-2 DETAILS
FIGURE 1B CK-2 & CK-2-2 DETAILS
FIGURE 1C CK-3-2 DETAILS
STANDOFF
2 PLACES
FILTER
HEAD
2 PLACES
THRU-HOLES
2 PLACES
STANDOFF
2 PLACES
FILTER
HEAD
2 PLACES
TIE ROD
2 PLACES
THRU-HOLES
2 PLACES
SCREWS
4 PLACES
FILTER
HEAD
2 PLACES
SCREWS
4 PLACES
O-RING
NUT
4 PLACES
WASHER
4 PLACES
O-RING
THRU-
HOLES
4 PLACES
O-RING
2950 Mechanic Street
Lake City, PA 16423-2095
Phone: 814/774-2631
Fax: 814/774-3482