enclosure. It is not necessary to remove the nuts from the
bolts. (See Figure 1).
Element(s) are shipped separately and must be installed
before filter is ready for service. Remove hex fastener(s)
from tie rod(s) in housing.
Remove element(s) from packaging and remove o-ring(s)
from end cap(s) of element(s). Install o-ring(s) in o-ring
groove(s) on hex fastener(s).
Install element(s) in housing so that tie rod protrudes
through small hole in endcap.
Thread hex fastener(s) onto the tie rod(s) and tighten so that
element(s) are held firmly in place. Do not over tighten.
(See Figure 1).
Repeat steps 11 thru 14 for each new element required.
(See Table 5 ).
Before closing housing, inspect baffle to make certain that
new elements have been installed in each position.
With enclosure o-rings in place, carefully lower enclosure
and raise all swing bolts over tabs. Tighten all nuts evenly.
Close drain valve; then slowly open inlet and outlet valves.
Close by-pass valves if provided.
Filter is now in service.
Drain oil removal filters every shift.
Check differential pressures regularly on coalescing and
particulate filters (AA, A, B, C, RA, RB, RC, and HT grades).
When differential pressure reaches 10 psid, install clean
elements. On adsorbing filters (grade RD), install clean
elements when hydrocarbon vapors are first detected
downstream or every six months, whichever comes first.
For correct replacement element model numbers, see label
on filter housing and/or the bottom endcap of the element.
(Refer to Table 6).
•
•
•
MAINTENANCE
6.
7.
8.
9.
10.
1.
2.
3.
4.
5.
DO NOT LOOSEN SWING BOLT NUTS BEFORE THE
FILTER IS COMPLETELY DEPRESSURIZED.
WARNING
INSTALLATION (PART 2 ELEMENT)
DESCRIPTION
Differential pressure gauge. (Only)
Differential pressure gauge with N.O. reed switch. (Only)
Differential pressure gauge with nylon tubing and brass tube fittings.
Differential pressure gauge with N.O. reed switch, nylon tubing and brass tube fittings.
Differential pressure gauge with stainless steel tubing and steel tube fittings (for HT units).
Differential pressure gauge with N.O. reed switch, stainless steel tubing and steel tube fittings (for HT units).
MODEL
NUMBER
PD-2 Gauge
PD-2/SW Gauge
PD-2 KIT
PD-2/SW KIT
PD-2/HT KIT
PD-2/HT SW KIT
PART
NUMBER
29-0255
29-0257
84-0129
84-0131
84-0130
84-0211
TABLE 6 DIFFERENTIAL PRESSURE GAUGE KITS:
ACCESSORIES
*Insert appropriate filtration grades here; for example F102-3500-C and
replacement element E101/102-625-C (five required).
FILTER
MODEL NO.
F102-1500-(*)
F102-2000-(*)
F102-3500-(*)
F102-5000-(*)
F102-7500-(*)
F102-10,000-(*)
F102-12,500-(*)
F102-15,000-(*)
F102-20,000-(*)
TABLE 5 REPLACEMENT PARTS
REPLACEMENT PARTS
REPLACEMENT
ELEMENT
MODEL NUMBER
E101/102-500-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
E101/102-625-(*)
MANUAL
DRAIN VALVE
14-0451
14-0451
14-0451
14-0451
14-0451
14-0451
14-0451
14-0451
14-0451
SWING BOLT
CLOSURE
O-RING
26-5464
26-5465
26-5465
26-5528
26-5529
26-5530
CONSULT FACTORY
CONSULT FACTORY
CONSULT FACTORY
ELEMENT
WEIGHT
LBS.
2.8
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
NUMBER OF
ELEMENTS IN
HOUSING
3
3
5
8
12
16
20
24
32