PAGE 5

4.1 LOCATION

WARNING

DO NOT INSTALL THIS DRYER SYSTEM IN AN ENVIRONMENT

OF CORROSIVE CHEMICALS, EXPLOSIVE GASSES, POISONOUS

GASSES, OR SATURATED STEAM HEAT.

Locate dryer system in a protected, well vented area where ambient

temperatures are between 40

o

F and 120

o

F. Allow sufficient clearance

over and around the dryer system for access to desiccant fill and drain

ports and controls.

Refer to SECTION 3.2 for dryer dimensions.

If this dryer system must be installed where ambient temperatures are

below 40

o

F, insulation and heat tracing must be properly installed on

the inlet piping, separator, prefilter, purge exhaust line and the

desiccant towers to prevent freezing of the equipment.

Position the dryer system in the upright position on a solid, level,

vibration free surface capable of supporting the dryer system’s weight.

Refer to SECTION 3.1 for dryer system specifications.

The dryer system should not be located in extremely dirty areas where

airborne contaminants can accumulate on the dryer system. If this

cannot be prevented, the dryer system should be cleaned periodically.

An accumulation of dirt on the precooler will greatly reduce its

efficiency. Accumulated dirt may also cause the inlet transfer valve to

fail.

INSTALLATION

SECTION 4

4.3 ELECTRICAL CONNECTIONS

WARNING

SERIOUS PERSONAL INJURY AND DAMAGE TO THE

DRYER SYSTEM WILL OCCUR IF THE DRYER SYSTEM IS

CONNECTED TO A POWER SOURCE OTHER THAN THE

VOLTAGE LISTED ON THE DATA TAG.

Connect the dryer system power cord to a 115V/1PH/60Hz power

source capable of supplying a minimum of 2 AMPS.

4.2 DESICCANT INSTALLATION

The desiccant was factory installed in both towers before the dryer

shipped.

4.5 FILL LUBRICATOR WITH OIL

The lubricator is located in the air line between the regulator and the

pre-cooler air motor. Fill the lubricator with Pneumatic Lubricating Oil

SAE10 AD220 (Van Air p/n 26-7032 quart).

4.4 INSTALLING THE PURGE MUFFLERS

Purge mufflers were shipped separately. They should

NOT be installed

until the dryer system has been operated for several hours. From

desiccant installation, some dust may be present in the desiccant

towers. Operating the dryer system with the mufflers installed im-

mediately after the towers have been filled with the desiccant or during

initial start up may cause the mufflers to clog. See

SECTION 5.6 for

purge muffler installation.

4.7 CONNECTING THE INLET AND OUTLET

The inlet and outlet of this dryer system are equipped with 2" 4-lug

couplings. Connect the inlet and outlet air hoses to the dryer system.

Remember to use SAFETY CLIPS.

4.6 CONNECT DRAIN LINES

Connect the automatic drains for the separator/prefilter and the prefilter

to an appropriate collection container. Filter and separator/prefilter

discharge may contain compressor lubricants. Comply with all regula-

tions concerning their disposal.