A

PPENDIX

B - ATM I

NSTALLATION FOR

A

CCESSIBILITY

For a side approach, where the depth of the alcove is
equal to or less than 15 inches (380 mm), the required
clear floor space is 30 inches by 48 inches (760 mm
by 1220 mm).

For a side approach, where the depth of the alcove is
greater than 15 inches (380 mm), then in addition to
the 48-inch (1220 mm) length, an additional
maneuvering clearance of 12 inches (350 mm) is
required.

Figures 4d. Clear Floor Space in Alcoves.

4.2.4.3 Surfaces for Wheelchair Spaces. Clear floor or ground spaces for wheelchairs shall comply with
4.5 (Ground and Floor Surfaces).

4.2.5

Forward Reach. If the clear floor space only allows forward approach to an object, the maximum

high forward reach allowed shall be 48 inches (1220 mm) (see Fig. 5(a)). The minimum low forward reach is
15 inches (380 mm). If the high forward reach is over an obstruction, reach and clearances shall be as shown
in Fig. 5(b).

Figures 4e. Clear Floor Space in Alcove.

Figure 5a. Forward reach, unobstructed.