4dc c – Triton RL23XX/RL5XXX (XS/X2/XP) User Manual
Page 4
M
idtopper
F
ield
i
nstallation
G
uide
4
dc c
onnections
Model 8100 DC power supply
DC power supply used in some model
91XX, and all RL23XX/RL5XXX terminals
(see
1
Note above)
Model RL16XX DC power supply
Refer to the following notes and figures (as applicable to the model type of the
terminal). Plug the DC power cord from the topper (In most cases, an 8-pin molex
connector) into any available 8-pin* DC output connector on the power supply.
* A 10-pin DC output connector on a power supply is reserved for the dispenser.
1
Note: All model 91XX (except units using the original hard-wired single
supply in some TDM or MiniMech configurations), RL23XX, and RL5XXX
configurations use a single or dual power supply with the same physical case
characteristics and DC connector layout. The DC power supply itself will be
mounted in different locations within the top enclosure of the cabinet, depending
on the model type.
2
Note: Refer to the following page. A Model 91XX with a TDM or MiniMech
dispenser and the original hard-wired single power supply will a require a power
extension cable (splitter).
Model 97XX DC power supply