Dc-p – Triton RL23XX/RL5XXX (XS/X2/XP) User Manual

Page 3

background image

d

irect

l

iGhtinG

(dc-p

owered

)

3

4. Feed the topper DC power cord through the large access hole in the cabinet.

With the topper mounting studs inserted into the four (4) corresponding

holes, place the assembly on top of the cabinet.

Note: Because of the slotted configuration of the mounting holes, there will

be some play (front-to-back) in the position of the topper assembly. Allow the

assembly to slide back until it stops.

These procedures are completed with the terminal AC power OFF.

1. Remove the topper assembly from the shipping container.

2. Locate and remove the dome plugs (if applicable) to uncover the topper

power cable access and mounting holes on the top of the ATM cabinet,

M

idtopper

i

nstallation

p

rocedure

3. Unlock and open the ATM control panel.

Figure 1. Location of topper access and

mounting holes.

Mounting Holes

Power Cord Access

Figure 3. Place nuts on topper mounting

studs and tighten down.

Figure 4. Connect the topper power

cable to the DC power supply.

5. To secure the topper assembly to the cabinet, place and tighten #8-32 nuts

on the four (4) mounting studs with a 3/8” nut driver. Plug the topper power

cable into any available 8-pin connector on the DC power supply.

Figure 2. Feed topper power cable

through cabinet access hole.