Electronic Leak Detector-VDC Page 4 eldvdcsm-rev0513

Available, as stated under principle of operation, is

an external output junction. If you wish to connect

the detection device to a solenoid which can shut

off air to the pump for example, or ring a bell, wire

into the box for this external connection thru the

7

/

8

"

diameter hole (commonly plugged) located on the

same end as the probe wire. The output connection

terminal has 100 watt power output and each chamber

FIGURE C

PROBE

CONNECTION TERMINAL

FOR 3 LEAD WIRE 15 ft. lg.

(P/N 150-026-000)

FROM ENCLOSURE BOX

(INCLUDED)

OUTPUT

CONNECTION TERMINAL

FOR POSSIBLE ALERT SYSTEM

OR TOTAL SYSTEM SHUT DOWN

(NOT INCLUDED)

(NOTE FIGURE “E”)

has independent connections. If combining the two

chambers, a four-wire lead, spliced before the external

device would be necessary. (See output connection

terminal Figure E.)

When Leak Detector is used with spill containment

Models SET1-A and SET2-A, the probes must be fit-

ted into special boss plugs. Order one Boss Plug Kit

475-098-000 per pump.

ALMHI

ALMLO

ALMHI

LOAD

SW2

CH2

SW1

C3

CH1

ALMLO

P1

LOAD

ENCLOSURE

BOX

ENCLOSURE

LID

See FIGURE D

Page 5

PROBE PICKUP BOARD

MOUNTED ON THE

ENCLOSURE LID

POWER BOARD

MOUNTED ON THE BACK

OF ENCLOSURE

PICTOGRAM FOR FUSE

FU1 POWER PROTECTION

12-32VDC

DRY CONTACT

ALARM OUTPUTS

AC OR DC

220V/5A

MAX

OUTPUTS

C6

C5

TS2

C7

1

TS1

+ - G

FU1

.5A

250V

P1

CR1

1

2

CR2

FU2

1A

250V

FU3

1A

250V

POWER

RTN

INC-

SENS

CW

R5

TS1

R6

INC-

SENS

CW

OPTIONAL EXTERNAL

OUTPUT JUNCTION

FOR SOLENOID

VALVES OR SIGNALS

PROBE

SENSITIVITY

ADJUSTMENT

ALMLO=ALARM ON

LOW CONDUCTIVITY

(HIGH RESISTANCE)

ALMHI=ALARM ON

HIGH CONDUCTIVITY

(LOW RESISTANCE)

AC POWER TERMINAL

FOR POWER CORD

(NOT INCLUDED)

Options: