Spill containment leak detection options drawing – SANDPIPER M15 Non-Metallic User Manual
Page 30

m15nmdl3sm-rev0713
Model M15 Non-Metallic Page 28
Spill Containment Leak Detection Options Drawing
Spill Containment LEAK DETECTION OPTION (ELECTRONIC)
Follow instructions found elsewhere in this manual, “Filling the
Spill Containment Chambers” when installing leak detectors.
Electronic Leak Detector Installation
Kit 032-037-000
100VAC
50Hz
or
110-120VAC
50/60Hz
or 220-240VAC
50/60Hz
Kit 032-045-000
12-32VDC
To install electronic leak detectors, remove the bottom ¼" NPT
pipe plug on the visual sight tube (item 49). Insert leak detector
into the ¼" pipe tee (item 48).
LEAK DETECTION OPTION (MECHANICAL)
Follow instructions found elsewhere in this manual, “Filling the
Spill Containment Chambers” when installing leak detectors.
Mechanical Leak Detector Installation
Kit 031-023-110
To install mechanical leak detectors, remove the bottom ¼" NPT
pipe plug on the visual sight tube (item 49). Insert leak detector
into the ¼" pipe tee (item 48).