m15nmdl3sm-rev0713

Model M15 Non-Metallic Page 25

SAFE AIR

EXHAUST

DISPOSAL

AREA

PUMP INSTALLATION AREA

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

MUFFLER

LIQUID

LEVEL

SUCTION

LINE

LIQUID

LEVEL

SUCTION

LINE

MUFFLER

MUFFLER

PUMPING HAZARDOUS LIQUIDS

When a diaphragm fails, the pumped

liquid or fumes enter the air end of the

pump. Fumes are exhausted into

the surrounding environment. When

pumping hazardous or toxic materials,

the exhaust air must be piped to an

appropriate area for safe disposal. See

illustration #1 at right.

This pump can be submerged if

the pump materials of construction

are compatible with the liquid being

pumped. The air exhaust must be piped

above the liquid level. See illustration #2

at right. Piping used for the air exhaust

must not be smaller than 1" (2.54

cm) diameter. Reducing the pipe

size will restrict air flow and reduce

pump performance. When the pumped

product source is at a higher level than

the pump (flooded suction condition),

pipe the exhaust higher than the

product source to prevent siphoning

spills. See illustration #3 at right.

CONVERTING THE PUMP FOR

PIPING THE ExHAUST AIR

The following steps are necessary

to convert the pump to pipe the exhaust

air away from the pump.

Use a #8 Torx or flat screwdriver

to remove the six self-tapping screws

(item 1-J).

Remove the muffler cap and muffler

(items 1-D and 1-F). The 1" NPT

molded threads in the air distribution

valve body (item 1-B).

Piping or hose may now be installed.

IMPORTANT INSTALLATION

NOTE: The manufacturer recommends

installing a flexible hose or connection

between the pump and any rigid

plumbing. This reduces stresses on

the molded plastic threads of the air

exhaust port. Failure to do so may

result in damage to the air distribution

valve body.

Any piping or hose connected to

the pump’s air exhaust port must be

physically supported. Failure to support

these connections could also result

in damage to the air distribution

valve body.