beautypg.com

SANDPIPER M05 Non-Metallic User Manual

Page 29

background image

m05nmdl2sm-rev0114

Model M05 Non-Metallic Page 27

SAFE AIR

EXHAUST

DISPOSAL

AREA

PUMP INSTALLATION AREA

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

MUFFLER

LIQUID

LEVEL

SUCTION

LINE

LIQUID

LEVEL

SUCTION

LINE

MUFFLER

MUFFLER

PUmPIng hazarDoUs lIQUIDs

When a diaphragm fails, the pumped

liquid or fumes enter the air end of the

pump. Fumes are exhausted into

the surrounding environment. When

pumping hazardous or toxic materials,

the exhaust air must be piped to an

appropriate area for safe disposal. See

illustration #1 at right.

This pump can be submerged if

the pump materials of construction

are compatible with the liquid being

pumped. The air exhaust must be piped

above the liquid level. See illustration #2

at right. Piping used for the air exhaust

must not be smaller than 3/8" diameter.

Reducing the pipe size will restrict air

flow and reduce pump performance.

When the pumped product source is at

a higher level than the pump (flooded

suction condition), pipe the exhaust

higher than the product source to

prevent siphoning spills. See illustration

#3 at right.

ConVerTIng The PUmP For

PIPIng The eXhaUsT aIr

The following steps are necessary

to convert the pump to pipe the exhaust

air away from the pump.

Use a #8 Torx or flat screwdriver

to remove the four self-tapping screws

(item 1-J) (Plastic Valves). Use a

Phillips screwdriver to remove four

machine screws (item 1-I) (Aluminum

Valves).

Remove the muffler cap and muffler.

The air distribution valve body has 3/8"

NPT threads for installation of alternate

mesh or sound dampening mufflers or

piped exhaust.

ImPorTanT InsTallaTIon noTe:

The manufacturer recommends

installing a flexible hose or connection

between the pump and any rigid

plumbing. This reduces stresses on

the molded plastic threads of the air

exhaust port. Failure to do so may

result in damage to the air distribution

valve body.

Any piping or hose connected to

the pump’s air exhaust port must be

physically supported. Failure to support

these connections could also result in

damage to the air distribution valve

body.

ConVerTeD eXhaUsT IllUsTraTIon

Illustration #1

Illustration #2

Illustration #3

1

24

Air Valve Assembly