beautypg.com

SANDPIPER M05 Non-Metallic User Manual

Page 27

background image

m05nmdl2sm-rev0114

Model M05 Non-Metallic Page 25

DUal PorTIng oPTIons

Several dual porting options are

possible. The pump can be converted

to a dual port arrangement on both

the suction and the discharge ends.

The porting can be configured to a

single suction and a dual discharge.

The porting can be changed to a dual

suction and a single discharge.

The above changes are possible

because the porting flange of the

elbows (items 17 & 18) are designed

to mate with ½" NPT or 1/2" BSP

(Tapered) connection.

DUal PorTIng oF BoTh sUCTIon

anD DIsCharge enDs oF

The PUmP

Converting the pump from the

standard single suction and discharge

porting configuration to dual porting at

each end is easy. Simply remove the

manifold seals and manifolds (items 33

and 23 from pump assembly drawing)

from the pump.

The discharge elbows and suction

elbows can be rotated 90° increments

(see arrows and optional positioning in

the Dual Porting Drawing.

sIngle PorTIng oF The sUCTIon

anD DUal PorTIng oF The PUmP

DIsCharge

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

discharge porting arrangement remove

the only the discharge manifolds and

manifold seals. Position the discharge

elbows in the desired direction at 90°

increments. (See arrows and optional

positioning in the Dual Porting Drawing.)

DUal PorTIng oF The sUCTIon

anD sIngle PorTIng oF The

PUmP DIsCharge

To convert the pump from the

standard single suction and single

discharge porting configuration to a dual

suction porting arrangement remove

the only the suction (bottom) manifolds

and manifold seals.

Position the suction elbows in the

desired direction at 90° increments.

(See arrows and optional positioning

in the Dual Porting Drawing.)

noTe: see repair Parts list on next page.

Read these instructions

completely, before

installation and start-up.

It is the responsibility of

the purchaser to retain

this manual for reference. Failure to

comply with the recommendations stated

in this manual will damage the pump, and

void factory warranty.

ImPorTanT