beautypg.com

Spill containment leak detection options drawing – SANDPIPER S15 Non-Metallic User Manual

Page 23

background image

s15nmdl3sm-rev0614

sandpiperpump

.

com

Model S15 Non-Metallic •

20

Spill Containment Leak Detection Options Drawing

Spill Containment LEAK DETECTION OPTION

(ELECTRONIC)

Follow instructions found elsewhere in this manual,

“Filling the Spill Containment Chambers” when installing

leak detectors.

Electronic Leak Detector Installation

Kit 032-037-000

100VAC

50Hz

or

110-120VAC

50/60Hz

or 220-240VAC

50/60Hz

Kit 032-045-000

12-32VDC

To install electronic leak detectors, remove the bottom

¼" NPT pipe plug on the visual sight tube (item 49). Insert

leak detector into the ¼" pipe tee (item 48).

LEAK DETECTION OPTION (MECHANICAL)

Follow instructions found elsewhere in this manual, “Filling

the Spill Containment Chambers” when installing leak

detectors.

Mechanical Leak Detector Installation

Kit 031-023-110

To install mechanical leak detectors, remove the bottom

¼" NPT pipe plug on the visual sight tube (item 49). Insert

leak detector into the ¼" pipe tee (item 48).

6: OPTIONAL