beautypg.com

Air distribution valve assembly, Atex compliant, Air distribution valve servicing – SANDPIPER S05 Metallic User Manual

Page 15: Important

background image

s05mdl1sm-rev0614

sandpiperpump

.

com

Model S05 Metallic •

12

Air Distribution Valve Assembly

ATEX Compliant

1-E

1-D

1-C

1-F

1-F

1-A

1-B

1-C

1-F

1-F

1-D

1-E

1-I

1-H

1-G

Main Air Valve Assembly Parts List

Item

Part Number

Description

Qty

1

031.191.000

Valve Assembly

1

1-A

031.132.000

Sleeve and Spool Set 1

1-B

095.106.157

Valve Body

1

1-C 132.038.357 Bumper

2

1-D

165.128.157

End Cap

2

1-E

171.076.330

Hex Flange Capscrew 1/4-20 x .75

8

1-F 560.101.360 O.Ring

4

1-G

530.031.550

Muffler

1

1-H

165.109.551

Muffler Cap

1

1-I

706.027.330

Machine Screw

4

Item Part number

Description

QTY

1

031.191.003

Valve Assembly

1

(same as above 031.191.003 except items 1-E, and 1-I)

1-E

171.076.115

Hex Flange Capscrew 1/4-20 x .75

8

1-I

706.027.115

Machine Screw

4

Main Air Valve Assembly Parts List

Item

Part Number

Description

Qty

1

031.186.000

Valve Assembly

1

(

Same as above 031.191.000 minus items 1-G, 1-H, and 1-I)

Item

Part Number

Description

Qty

1

031.186.003

Valve Assembly

1

(Same as above 031.186.003 except item 1-E)

1.E

171.076.115

Hex Flange Capscrew 1/4-20 x .75

8

Note: Pumps equipped with this valve assembly are

ATEX compliant when a metal muffler is used.

Air Distribution Valve Servicing

See repair parts drawing, remove screws.
Step 1: Remove hex capscrews (1-E).
Step 2: Remove end cap (1-D).
Step 3: Remove spool part of (1-A) (caution: do not scratch).
Step 4: Press sleeve (1-A) from body (1-B).
Step 5: Inspect bumpers (1-C) and o-rings (1-F).
Step 6: Lightly lubricate O-Rings (1-F) on sleeve (1-A).
Step 7: Press sleeve (1-A) into body (1-B).
Step 8: Reassemble in reverse order, starting with step 3.

Note: Sleeve and spool (1-A) set is match ground to a specified clearance

sleeve and spools (1-A) cannot be interchanged.

IMPORTANT

Read these instructions completely, before installation

and start-up. It is the responsibility of the purchaser

to retain this manual for reference. Failure to comply

with the recommendations stated in this manual will

damage the pump, and void factory warranty.

4: AIR

END