Installation, Technical specifications – Lincoln Electric IM764 RED-D-ARC EX350i User Manual
Page 8
![background image](/manuals/363652/8/background.png)
EX350i
A-1
INSTALLATION
A-1
TECHNICAL SPECIFICATIONS -
RED-D-ARC EX350i
INPUT AC VOLTAGE & DC OUTPUT
*
Overall Length Including Handle, 27.8” (706mm)
Voltage
200
208
230
380
400
415
460
575
200
208
230
380
400
415
460
575
Phases
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
300Amps @
32Volts(100%)
Not
Recommended
76
69
Not
Recommended
Not
Recommended
41
36
31
41
39
36
23
22
22
19
16
350Amps @
34Volts(60%)
Not
Recommended
94
85
Not
Recommended
Not
Recommended
64
42
37
50
50
42
28
27
26
23
18
Line Cord
AWG
2
4
---
6
8
8
8
6
8
8
8
8
8
8
Fuse size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
50A
50A
50A
50A
35A
EX350i INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Select The output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP TO 200FT.(61m)
1/0
1/0
200-250 FT. (61-76m)
1/0
2/0
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2
Product
Name
EX350i
Output
Range
(Continuous)
AMPS
5-425
Open
Circuit
80 VDC
Ordering
Information
K1757-2
Input AC
Voltage
200
208-230/
380-400/
415-460/
575
1 & 3
PHASE
50/60Hz
Rated DC Output
Amps/Volt/
Duty Cycle
350/34/60%
300/32/100%
Height
Width
Depth
Weight
14.8”(373mm)
13.3”(338mm) 27.8” *(706mm*) 84.0 Lbs.(38.0 Kg)
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
STORAGE TEMPERATURE RANGE
-40°C to +40°C
OPERATING TEMPERATURE RANGE
-20°C to +40°C