beautypg.com

Operation – Lincoln Electric IM764 RED-D-ARC EX350i User Manual

Page 20

background image

B-9

OPERATION

B-9

EX350i

AUXILIARY POWER

• 115VAC, 42VAC and 24VAC power is available

from the two 14-pin amphenols on the rear of the
unit. These supplies are intended to supply power
for auxiliary equipment like wire feeders and the TIG
Module.

• 115VAC supply is rated at 2 amps and is protected

by a 2.5 amp breaker located by the amphenol.

• 42 VAC supply is rated at 5.5 amps and is protected

by a 10 amp breaker located by the amphenol.

• 24 VAC supply is rated at 5.5 amps and is protected

by a 10 amp breaker located by the amphenol.

LIMITATIONS

• The EX350i is not recommended for processes

other than those listed.

• The EX350i can only be used with the recommend-

ed equipment and options.

RECOMMENDED PROCESSES

Properly equipped, the EX350i supports GMAW,
FCAW, SMAW, GMAW-P, GTAW and CAC-A
processes for a variety of materials, including mild
steel, stainless steel, cored wires, and aluminum.