Installation, Technical specifications – Lincoln Electric IM799 POWER WAVE F355i(CE) User Manual
Page 10
A-1
INSTALLATION
POWER WAVE F355i (CE)
A-1
TECHNICAL SPECIFICATIONS -
POWER WAVE F355i
INPUT AC VOLTAGE & DC OUTPUT
Product
Ordering
Input AC
Rated DC Output Output
Weight Dimensions
Name Information Voltage
Amps/Volts/Duty Cycle
Range
with Cord
HxWxD
(continuous)
POWER
K2260-1
380-415
350A / 34V / 60%
14.6” x 17.2” x 27.6”*
WAVE
K2260-2
AMPS
110.0 lbs.
(371 x 437 x 701*)mm
F355i
60/50 Hz
5-425
(50.0. kg.)
3 Phase
300A / 32V /100%
* Includes Mounting
Brackets
* Overall Length without Mounting Brackets, 21.06” (535mm)
Voltage
380
400
415
Phases
3
3
3
300Amps @
32Volts(100%)
23
22
22
350Amps @
34Volts(60%)
28
27
26
Line Cord
10mm
2
10mm
2
10mm
2
Fuse size
40A
40A
40A
POWER WAVE F355i INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP 200FT.(61m)
2/0
2/0
200-250 FT. (61-76m)
2/0
2/0
*
Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.