A-1

INSTALLATION

POWER WAVE F355i (CE)

A-1

TECHNICAL SPECIFICATIONS -

POWER WAVE F355i

INPUT AC VOLTAGE & DC OUTPUT

Product

Ordering

Input AC

Rated DC Output Output

Weight Dimensions

Name Information Voltage

Amps/Volts/Duty Cycle

Range

with Cord

HxWxD

(continuous)

POWER

K2260-1

380-415

350A / 34V / 60%

14.6” x 17.2” x 27.6”*

WAVE

K2260-2

AMPS

110.0 lbs.

(371 x 437 x 701*)mm

F355i

60/50 Hz

5-425

(50.0. kg.)

3 Phase

300A / 32V /100%

* Includes Mounting

Brackets

* Overall Length without Mounting Brackets, 21.06” (535mm)

Voltage

380
400
415

Phases

3
3
3

300Amps @

32Volts(100%)

23
22
22

350Amps @

34Volts(60%)

28
27
26

Line Cord

10mm

2

10mm

2

10mm

2

Fuse size

40A
40A
40A

POWER WAVE F355i INPUT CURRENT

OUTPUT CABLES, CONNECTIONS AND LIMITATIONS

Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs

Input 50/60 Hz

Output

Recommended

Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:

DUTY CYCLE

100%

60%

CURRENT

300
350

LENGTH UP 200FT.(61m)

2/0
2/0

200-250 FT. (61-76m)

2/0
2/0

*

Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.