SEMIAUTOMATIC PW450

CURRENT CALIBRATION (continued)

CALIBRATION

2. Locate the 10 turn trimmer potentiometer

located on the control board. It is the only
trimmer on the board. If the trimmer is not
accessible with the control board installed,
then the board must be removed and laid
on the top of the PC board compartment.
Be sure the control board is insulated from
the other boards and the case parts. All
wiring plugs must be connected to the con-
trol board. See Figure 8.

WHEN THE MACHINE CASE IS REMOVED
HIGH VOLTAGE POINTS ARE EXPOSED.

STAND DIRECTLY IN FRONT OF MACHINE
UNDER TEST.

EXPLODING PARTS CAN CAUSE INJURY.
FAILED PARTS CAN EXPLODE OR CAUSE
OTHER PARTS TO EXPLODE WHEN POWER
IS APPLIED. ALWAYS WEAR A FACE SHIELD
AND LONG SLEEVES WHEN SERVICING.

WHEN LOADING THE MACHINE WITH THE
CASE PARTS REMOVED. BE CAREFUL NOT
TO OVER HEAT THE MACHINE.

3. NOTE: If a wire feeder is NOT connected

to the Power Wave the machine
may not display output volts.

4. Connect the resistance grid load to the

machine’s output terminals. Connect the
reference ammeter in series with the grid
load. See Figure 9.

POWER WAVE CALIBRATION

WARNING

FIGURE 9 – RESISTANCE GRID LOAD CONNECTIONS

CAUTION

POWER WAVE

RESISTANCE

GRID

LOAD

AMMETER

VOLT METER

+