Installation – Lincoln Electric IM691 POWER WAVE 455R (CE) User Manual
Page 8

A-1
INSTALLATION
POWER WAVE 455/R (CE)
A-1
TECHNICAL SPECIFICATIONS - POWER WAVE 455/R CE (K1761-3)
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
PHYSICAL DIMENSIONS
TEMPERATURE RANGES
INPUT AT RATED OUTPUT - THREE PHASE ONLY
INPUT VOLTS
380V - 50/60HZ.
380V - 50/60HZ.
415V - 50/60HZ.
415V - 50/60HZ.
OPEN
CIRCUIT
VOLTAGE
75 VDC
INPUT
VOLTAGE /
FREQUENCY
380-50 HZ
415-50 HZ
HEIGHT
26.10 in
663 mm
WIDTH
19.86 in
505 mm
DEPTH
32.88 in
835 mm
WEIGHT
256 lbs.
116 kg.
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
40
40
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG[IEC] SIZES
(MM2)
10 (6)
10 (6)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG[IEC] SIZES
(MM2)
8 (10)
8 (10)
INPUT AMPERE
RATING ON
NAMEPLATE
36
33
AMPS/
DUTY
CYCLE
400/100%
400/100%
PROCESS CURRENT RANGES (DC)
MIG/MAG
FCAW
SMAW
Pulse
STT
CURRENT
50-570 Amps
40-570 Amps
30-570 Amps
5-750 Amps
40-325 Amps
PULSE
VOLTAGE
RANGE
5 - 55 VDC
AUXILIARY POWER
(CIRCUIT BREAKER
PROTECTED)
40 VDC AT
10 AMPS
220 VAC AT
5 AMPS
PULSE AND
BACKGROUND
TIME RANGE
100 MICRO SEC.
-
3.3 SEC.
STT PARAMETERS
PEAK & BACK-
GROUND CURRENT
40-325 AMPS
CURRENT
RANGE
5 - 570
PULSE
FREQUENCY
0.15 - 1000 Hz
INPUT
CURRENT
36
48
33
44
IDLE
POWER
400 Watts
Max.
POWER FACTOR
@ RATED OUPUT
.89 MIN.
EFFICIENCY
@ RATED OUPUT
88%
OUTPUT CONDITIONS
500A@40V. 60%
500A@40V. 60%
OPERATING TEMPERATURE RANGE
-20°C to +40°C
STORAGE TEMPERATURE RANGE
-40°C to +40°C