beautypg.com

Installation – Lincoln Electric IM691 POWER WAVE 455R (CE) User Manual

Page 8

background image

A-1

INSTALLATION

POWER WAVE 455/R (CE)

A-1

TECHNICAL SPECIFICATIONS - POWER WAVE 455/R CE (K1761-3)

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

PHYSICAL DIMENSIONS

TEMPERATURE RANGES

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT VOLTS

380V - 50/60HZ.
380V - 50/60HZ.
415V - 50/60HZ.
415V - 50/60HZ.

OPEN

CIRCUIT

VOLTAGE

75 VDC

INPUT

VOLTAGE /

FREQUENCY

380-50 HZ
415-50 HZ

HEIGHT

26.10 in

663 mm

WIDTH

19.86 in

505 mm

DEPTH

32.88 in

835 mm

WEIGHT

256 lbs.

116 kg.

TYPE 75°C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

40
40

TYPE 75°C

GROUND WIRE

IN CONDUIT

AWG[IEC] SIZES

(MM2)

10 (6)
10 (6)

TYPE 75°C

COPPER WIRE

IN CONDUIT

AWG[IEC] SIZES

(MM2)

8 (10)
8 (10)

INPUT AMPERE

RATING ON

NAMEPLATE

36
33

AMPS/

DUTY

CYCLE

400/100%
400/100%

PROCESS CURRENT RANGES (DC)

MIG/MAG

FCAW

SMAW

Pulse

STT

CURRENT

50-570 Amps
40-570 Amps
30-570 Amps

5-750 Amps

40-325 Amps

PULSE

VOLTAGE

RANGE

5 - 55 VDC

AUXILIARY POWER

(CIRCUIT BREAKER

PROTECTED)

40 VDC AT

10 AMPS

220 VAC AT

5 AMPS

PULSE AND

BACKGROUND

TIME RANGE

100 MICRO SEC.

-

3.3 SEC.

STT PARAMETERS

PEAK & BACK-

GROUND CURRENT

40-325 AMPS

CURRENT

RANGE

5 - 570

PULSE

FREQUENCY

0.15 - 1000 Hz

INPUT

CURRENT

36
48
33
44

IDLE

POWER

400 Watts

Max.

POWER FACTOR

@ RATED OUPUT

.89 MIN.

EFFICIENCY

@ RATED OUPUT

88%

OUTPUT CONDITIONS

[email protected]%

500A@40V. 60%

[email protected]%

500A@40V. 60%

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-40°C to +40°C