A-9

INSTALLATION

POWER WAVE

®

405M

A-9

I / O RECEPTACLE SPECIFICATIONS

TABLE A.2

WIRE FEEDER RECEPTACLE

PIN

LEAD#

FUNCTION

A

53

Communication Bus L

B

54

Communication Bus H

C

67A

Electrode Voltage Sense

D

52

0vdc -

E

51

+40vdc +

TABLE A.3

VOLTAGE SENSE RECEPTACLE

PIN

LEAD#

FUNCTION

3

21A

Work Voltage Sense

TABLE A.4

RS232 RECEPTACLE

PIN

LEAD#

FUNCTION

2

253

RS232 Receive

3

254

RS232 Transmit

4

#

Pin5

5

#

Pin4

6

# #

Pin20

20

# #

Pin6

7

251

RS232 Common

DIP SWITCH SETTINGS AND LOCATIONS

DIP switches on the P.C. Boards allow for custom configuration of
the POWER WAVE

®

. To access the DIP switches:

ELECTRIC SHOCK can kill.

1. Turn off power to the power source at the dis-

connect switch.

• Insulate yourself from the work and ground.
• Always wear dry insulating gloves.

------------------------------------------------------------------------------------------

2. Remove the wrap around cover from the power source.
3. The control board is on the center assembly facing the case front.

Locate the 8-position DIP switch and look for switch 8 of the DIP
switch.

4. Using a pencil or other small object, slide the switch to the OFF

position if the work sense lead is NOT connected. Conversely, slide
the switch to the ON position if the work sense lead is present.

5. Replace the wrap around and screws. The PC board will “read” the

switch at power up, and configure the work voltage sense lead
appropriately.

CONTROL BOARD DIP SWITCH:

switch 1 = reserved for future use
switch 2 = reserved for future use

switch 3 = equipment group 1 selcted (default=off)
switch 4 = equipment group 2 selcted (default=off)

switch 5 = reserved for future use
switch 6 = reserved for future use
switch 7 = auto mapping
switch 8 = work sense lead

(See Figure A.8 Dual Head Boom Feeder)

switch 8*

work sense lead

off work sense lead not connected
on work sense lead connected

*Factory setting for Switch 8 is OFF.

switch 7

auto mapping

off auto mapping enable-default

on auto mapping disabled

CONTROL BOARD (DIP Switch Location)

FIGURE A.7

WARNING

}

40VDC

FIGURE A.8