Installation, Technical specifications – Lincoln Electric IM845 POWER WAVE 355M User Manual
Page 8

A-1
INSTALLATION
POWER WAVE
®
355M
A-1
TECHNICAL SPECIFICATIONS -
POWER WAVE
®
355M
INPUT AC VOLTAGE & DC OUTPUT
Product Ordering Input AC
Rated DC Output Output
Weight Dimensions
Name Information Voltage
Amps/Volts/Duty Cycle
Range
with Cord
HxWxD
(continuous)
200
350A / 34V / 60%
14.8” x 13.3” x
POWER
K2368-1
208-230/
27.8”*
WAVE
380-400/
AMPS
(81.5 lbs.)
(373 x 338 x
355M
415-460/
5-425
(37.0 kg.)
706*)mm
575
300A / 32V /100%
1& 3 Phase
* Includes Handles
50/60 Hz
* Overall Length Including Handle, 21.6” (549mm) without handle.
Insulation Class 180 (H)
Voltage
200
208
230
380
400
415
460
575
200
208
230
380
400
415
460
575
Phases
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
300Amps @
32Volts(100%)
Not
Recommended
76
69
Not
Recommended
Not
Recommended
41
36
31
41
39
36
23
22
22
19
16
350Amps @
34Volts(60%)
Not
Recommended
94
85
Not
Recommended
Not
Recommended
64
42
37
50
50
42
28
27
26
23
18
Line Cord
AWG
2
4
---
6
8
8
6
6
8
8
8
8
8
8
Fuse size
---
125A
125A
---
---
80A
70A
50A
80A
80A
70A
40A
40A
40A
40A
30A
POWER WAVE
®
355M INPUT CURRENT
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Output
Recommended
Note 1. Not rated is indicated by 4-xʼs in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
Select The output cable size based upon the following chart.*
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:
DUTY CYCLE
100%
60%
CURRENT
300
350
LENGTH UP 200FT. (61m)
2/0
2/0
200-250 FT. (61-76m)
2/0
2/0
Notes
Note 1
Note 2
Note 2
Note 1
Note 1
Note 2
Note 2
Note 2
*