TROUBLESHOOTING

E-3

POWER FEED 10 / R

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your

Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE CAUSE

RECOMMENDED

COURSE OF ACTION

Variable or “hunting arc.

Poor arc striking with sticking or

“blast-offs”, weld porosity, narrow

and ropy looking bead, or electrode

stubbing into plate while welding.

1. Wrong size, worn and/or melted

contact tip.

2. Worn work cable or poor work

connection.

3. Loose electrode or work cable

connections.

4. Wrong polarity. - Make sure

electrode polarity is correct for

process being used.

5. Gas nozzle extended beyond

gun tip or wire stickout too long

while welding.

6. Poor gas shielding on processes

requiring gas. - Check gas flow

and mixture.

1. Improper procedures or tech-

niques. - See “Gas Metal Arc

Welding Guide” (GS-100).

2. Improper gas shielding - Clean

gas nozzle. Make certain that

gas diffuser is not empty or

turned off. Make certain gas flow

rate is proper.

3. Remove gun liner and check

rubber seal for any sign of dete-

rioration or damage. Be sure set

screw in connector block is in

place and tightened against the

liner bushing.

If all recommended possible areas of

misadjustment have been checked

and the problem persists, Contact

your local Lincoln Authorized

Field Service Facility.