RED-D-ARC LN-25™ PRO DUAL POWER (CE)

DEFINITION OF WELDING TERMS

WFS

• Wire Feed Speed

CC

Constant Current

CV

Constant Voltage

GMAW

• Gas Metal Arc welding

SMAW

Shielded Metal Arc welding

FCAW

Flux Core Arc Welding

GENERAL DESCRIPTION

General Physical Description
The Red-D-Arc LN-25™ PRO DUAL POWER is spe-
cially engineered to be the most rugged portable wire
feeder available.

The plastic case is molded from a high impact, flame
retardant plastic for durability and low weight. The
patent pending design keeps the internal components
protected and dry.

The heart of the Red-D-Arc LN-25™ PRO DUAL
POWER is the 2 roll MAXTRAC™ drive. The patent-
ed features on the wire drive offer tool-less changing
of the drive rolls and wire guides for quick spool
changes. A tachometer controlled motor powers the
patent pending drive rolls for smooth, steady feeding
without slippage.

General Functional Description

The Red-D-Arc LN-25™ PRO DUAL POWER as
designed is a simple, robust feeder. Standard features
include a calibrated wire feed speed dial, 2 step/trig-
ger interlock switch, CV-CC switch, Gas Purge and
Cold Feed.

The Dual Power LN-25 PRO has a patent pending electron-
ic circuit to allow easy transition from Across the Arc opera-
tion to Control Cable operation. Simply connect the work clip
and the electrode lead for Across the Arc welding.
Whenever a control cable is connected, the feeder switches
to Control Cable operation.

To improve contactor life, the contactor is always closed
when operating as a control cable feeder.

RECOMMENDED PROCESSES

• GMAW
• FCAW

PROCESS LIMITATIONS

• GMAW-P procedures must be qualified by the cus-

tomer.

• Across-the-Arc models are not recommended for

stitch or spot welding.

EQUIPMENT LIMITATIONS

• The duty cycle of the wire feeder is 325A, 100% and

450A, 60%. Duty cycle is based upon the amount of
welding performed in a 10 minute period.

• The maximum spool size is 45 lb, 12" diameter.
• Maximum FCAW gun length is 15 ft.
• Maximum GMAW gun length is 25 ft.
• Push-pull guns do not work with the wire feeder.
• Digital displays do not show preset voltage.

RECOMMENDED POWER SOURCES

• CV-250
• CV-300
• CV-305
• CV-400
• CV-655
• DC-400
• DC-600
• DC-655
• STT-II
• Invertec V-350 PRO
• Invertec V-450 PRO
• Multi-Weld 350
• Ranger 10,000

• Ranger 3 Phase
• Ranger GXT
• Ranger 250
• Ranger 305
• SAE-400
• Pipeliner 200G
• Classic 300
• Vantage 300
• Vantage 400
• Vantage 500