Installation, A-6 across the arc set-ups – Lincoln Electric IM994 RED-D-ARC LN-25 PRO EXTREME (CE) User Manual
Page 15

A-6
INSTALLATION
RED-D-ARC LN-25™ PRO DUAL POWER (CE)
A-6
ACROSS THE ARC SET-UPS
CC Power Sources with Output Terminals Always
Hot (See Figure A.5)
If the power source has a Remote/Local switch, place
the switch in the Local position.
Place the CV/CC switch in the feeder in the "CC" posi-
tion.
CV
Power Sources with Stud Connectors and
Remote/Local Switch (See Figure A.6)
Place the power source Remote/Local switch in the
Local position.
Place CV/CC switch in the feeder in the "CV" position.
CC Power Source
Ranger 250, 250 LPG
Ranger 305G, 305D
Commander 300
Vantage 300, 400, 500
Air Vantage 500
Ranger 10,000
Ranger 3 phase
SAE 400 with CV adapter
Engine Driven welder with
Wire Feed Module
Work
Electrode
Work c lip
RED-D-ARC
LN-25™ PRO DUAL POWER
CV-655
DC-400
DC-600
DC-655
V450-Pro
Work
Electrode
Work c lip
RED-D-ARC
LN-25™ PRO DUAL POWER
FIGURE A.5
FIGURE A.6
K#
K2614-2
KP1695-XX
KP1696-XX
KP1697-XX
See Magnum Literature
K1803-1
Description
RED-D-ARC LN-25™ PRO Dual Power
Drive Roll Kit
Welding Gun
CC power Source
Welding Cables
POWER SOURCE TO RED-D-ARC LN-25™ PRO DUAL POWER
CABLE CONNECTION DIAGRAMS
K#
K2614-2
KP1695-XX
KP1696-XX
KP1697-XX
See magnum Literature
K1803-1
Description
RED-D-ARC LN-25™ PRO Dual Power
Drive Roll Kit
Welding Gun
CV power Source
Welding Cables