beautypg.com

Accessories, Automatic wire feeders, Field installed options – Lincoln Electric IM770 IDEALARC CV-525 User Manual

Page 24

background image

C-1

ACCESSORIES

C-1

The CV-525 can be used to power any of
the following Lincoln Wire feeders:

SEMI-AUTOMATIC WIRE FEEDERS

LN-9*

LN-9 GMA

LN-7 GMA*

LN-23P

LN-742

LN-25

LN-7

LN-8

Arcweld AWF-2

Arcweld AWF-4

Panasonic-style wire feeder

OTC-style wire feeder

AUTOMATIC WIRE FEEDERS

#

NA-3

NA-5R

NA-5

#

Cold starting for sub-arc cannot be used. (It must be jumpered out. See

Auto Feeder manual)

FIELD INSTALLED OPTIONS

REMOTE OUTPUT CONTROL K857 WITH K864
ADAPTER)

The K857 has a 6-pin MS-style connector. The K857
requires a K864 adapter cable which connects to the
WF-L(14-pin) connector on the CV-525.

REMOTE CONTROL ADAPTER CABLE (K864)
A “V” cable 12” (.30m) long to connect a K857

Remote Control (6 pin connector) with a wire-feeder
(14-pin connector) and the machine (14-pin connec-
tor). If a remote control is used alone the wire-feeder
connection is then not used.

UNDERCARRIAGES (K817P, K841)

For easy moving of the machine, optional undercar-
riages are available with polyolefin wheels (K817P) or
a platform undercarriage (K841) with mountings for
two gas cylinders at rear of welder.

Install per instructions provided with undercarriage.

CV-525

S T R A I G H T P L U G ( 1 4 P I N )
T O P O W E R S O U R C E

C A B L E R E C E P T A C L E ( 6 S O C K E T )

C A B L E R E C E P T A C L E ( 1 4 S O C K E T )

T O : K 8 5 7 R E M O T E C O N T R O L

T O : L N - 7 W I R E F E E D E R S