CV-525

A-1

INSTALLATION

TECHNICAL SPECIFICATIONS CV-525 KA1454-1, KA1454-2

Volts at Rated Amperes

34

36.5

39

40.25

Auxiliary Power

36VAC-10Amps

for Gas Regulator

use only

Amps

400
450
500
525

Maximum Open Circuit Voltage

46

Duty Cycle

100% Duty Cycle

60% Duty Cycle
50% Duty Cycle
45% Duty Cycle

Current Range

60-525

INPUT - THREE PHASE ONLY

OUTPUT

1Also called

inverse time

or

thermal/magnetic

circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

RECOMMENDED INPUT WIRE AND FUSE SIZES

Standard

Voltage

380-415V/50/60Hz (KA1454-1)

220/380-415/440V/50/60Hz (KA1454-2)

50% Duty Cycle

48

83/48/41

45% Duty Cycle

49

84/49/42

100% Duty Cycle

45

77/45/39

60% Duty Cycle

47

81/47/40

Input Current at Rated Output

RATED OUTPUT

INPUT

VOLTAGE

380-415V

220/380-415/440V

TYPE 75

°

C

(SUPER LAG)

OR BREAKER

SIZE (AMPS)

1

100A

175A/100A/80A

TYPE 75

°

C

GROUND WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

8 (10)

6(16)/8(10)/8(10)

TYPE 75

°

C

COPPER WIRE

IN CONDUIT

AWG(IEC-MM

2

) SIZES

40

°

C (104

°

F) Ambient

6 (16)

4(25)/6(16)6(16)

INPUT AMPERE

RATING ON

NAMEPLATE

50

86/50/43

FREQUENCY

Hz

50/60
50/60

PHYSICAL DIMENSIONS

HEIGHT

27.5 in

699 mm

WIDTH

22.25 in

565 mm

DEPTH

32.0 in

813 mm

WEIGHT

385 lbs.

175 kg.