A-4

INSTALLATION

CV-525

A-4

Installation of Equipment Required for
Recommended Processes

Note:

Only one wire feeder should be connected to the

CV-525 power source. If two or more are connected to
the CV-525 power source it will not work properly.

WIRE FEEDER CONTROL CABLE CONNECTIONS

For control cable with WF-L(14-pin) connector:

Connect control cable to WF-L connector on the front
panel of the machine labeled WF-L. See the appropri-
ate connection diagram for the exact instructions for
the wire feeder being used. Refer to

115VAC and

42VAC Auxiliary Power and Control Connections

section for connector pin functions.

A cover (Lincoln Electric Part Number S17062-3) is
available for the unused WF-L connector to protect it
against dirt and moisture.

CONNECTION OF CV-525 TO LN-22 OR LN-25

a) Turn off all power.

b) Connect a jumper between pins

C to D

in WF-L

connector plug, (a K484 14-pin jumper plug is
available).

c) Connect the electrode cable to the output terminal

of polarity required by electrode. Connect the work
lead to the other terminal.

d) Place the OUTPUT CONTROL Switch at

LOCAL

position unless a Remote Control is connected to
the CV-525.

NOTE: The output terminals are energized at all

times.

The Feeder Ready LED will stay off when a wire feed-
er is connected to the WF-L connector.

CONNECTION OF CV-525 TO ARCWELD AWF
FEEDERS, OR PANASONIC STYLE / OTC STYLE
WIRE FEEDERS.

a) Turn off all power.

b) Connect the ARCWELD AWF or Panasonic Style

wire feeder to WF-AWF/P receptacle. Connect
OTC style wire feeder to WF-O receptacle.

c) Place the output control switch to the

REMOTE

position.

d) Turn on the input power. The Feeder Ready LED

should lit up if one of the wire feeders listed in
step (b) is connected correctly to the CV-525.