beautypg.com

Diagrams – Lincoln Electric IM500 IDEALARC CV-300 User Manual

Page 33

background image

F-6

DIAGRAMS

F-6

CV-300

CV POWER SOURCE TO AN LN-25 / K444-1

Only qualified persons should install, use or

service this machine

.

using the disconnect switch at the fuse box

WARNING

T

urn off input power to the Welding Power Source

Before connecting the wire feeder.

ELECTRI

C

SHOCK

CAN KILL

N

.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN POWER "OFF",

ELECTRODE CABLE

-

+

14 PIN

AMPHENOL

POWER SOURCE

CV/CV-I

TO WOR

K

LN-25

WIRE FEEDER

O

PTIONA

L

K

484 JUMPER

PLU

G

O

PTIONAL K864 REMOT

E

CONTROL ADAPTER

W

ITH K444-1 OPTIO

N

N.D.N.D.

N.C.

N.C. CONNECT THE K484 JUMPER PLUG TO THE 14 PIN RECEPTACLE OF THE

K864 REMOTE CONTROL ADAPTER. CONNECT THE 6 PIN PLUG FROM THE

LN-25 (WITH K444-1 OPTION) TO THE 6 PIN RECEPTACLE OF THE K864

N

.D. THE POWER SOURCE TERMINALS ARE ALWAYS "HOT" WHEN THE K484 JUMPER

PLUG KIT IS INSTALLED.

REVERSE ELECTRODE AND WORK CABLES AT POWER SOURCE, SWITCH LN-25 POLARITY SWITCH.

REMOTE CONTROL ADAPTER. SWITCH THE POWER SOURCE "LOCAL/REMOTE" SWITCH TO REMOTE.

S20663

CV/CV-I POWER SOURCE TO LN-25 WITH K444-1 OPTION CONNECTION DIAGRAM

6-18-93