TROUBLESHOOTING

E-4

CV-300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Thermal Protection Indicator light is
on.

Machine does not have maximum
output

Machine will not shut off.

Variable or sluggish welding arc.

Digital meters do not light

- or -

Digital meter display is incorrect.

1. Thermostat circuit has opened.

2. Faulty Control PC Board.

1. Faulty Control PC Board.

2. Voltage Adjust potentiometer

defective.

3. Voltage Adjust potentiometer

leads open.

1. Defective power switch.

1. Poor work or electrode

connection.

2. Welding leads too small.

3. Welding current or voltage

too low.

4. Defective SCR bridge.

1. Faulty Meter PC board.

2. Faulty Control PC Board.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.