TROUBLESHOOTING

E-6

CV-300

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Output control not functioning on
Remote Control.

Voltage Adjust not functioning on the
machine.

1. Local/Remote switch in wrong

position.

2. Faulty Local/Remote switch.

3. Faulty Remote Control poten-

tiometer.

4. Leads or connections open in

control circuit.

5. Faulty Control PC board.

1. Local/Remote switch in the

wrong position.

2. Faulty Local/Remote switch.

3. Faulty Voltage Adjust

potentiometer.

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

OPTIONS TROUBLESHOOTING GUIDE

K857 (or other) Remote Output Control