E-3

TROUBLESHOOTING

E-3

CV-300

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS

RECOMMENDED

COURSE OF ACTION

Machine has no output.

Machine has minimum output and no
control.

Machine has low output and no con-
trol.

1. Secondary contactor circuit (2

and 4 wire feeder receptacle) not
working.

2. Electrode or work lead loose or

broken.

3. Defective PC Board.

4. Protective circuits operating due

to output short circuit.

5. If using an LN-25, K484 jumper

plug kit not making connection
between 2 & 4 in wire feeder
receptacle.

6. If welding with 1/16" aluminum

wire and machine is flashing E00.

1. Voltage Control misconnected.

1. Open in feedback circuitry.

2. Faulty PC Board.

3. Voltage Adjust potentiometer
circuit open (lead 75).

If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.

MACHINE TROUBLESHOOTING GUIDE

Not all trouble conditions can be recognized by the PC board, and displayed as error codes. The following guide
covers most other trouble conditions.