Installation – Lincoln Electric IM765 Commander 500 User Manual
Page 17

A-9
INSTALLATION
COMMANDER 500 CUMMINS
A-9
CONNECTION OF AN LN-23P
WIRE
FEEDER TO THE COMMANDER 500 CUM-
MINS
•
Shut the welder off.
•
Connect the LN-23P per instructions on the appro-
priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
COMMANDER 500 CUMMINS, a K350-1 adapter kit
must be used.
•
Set the
“
WIRE FEEDER VOLTMETER
”
switch to
“
-
”
.
•
Set the
“
SELECTOR
”
switch to
“
CV-WIRE
”
position.
•
Set the
“
WELDING TERMINALS
”
switch to
“
REMOTELY CONTROLLED
”
.
•
Set the ARC CONTROL to desired crispness. SOFT
for MIG - CRISP for INNERSHIELD.
•
Set the
“
IDLE
”
switch to the
“
HIGH
”
position. If you
are using an LN-23P with the K350-1 adapter kit, the
electrode is not energized until the gun trigger is
closed.
CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500 CUMMINS
For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the COMMANDER 500
CUMMINS, refer to the NA-3 Welding System instruc-
tion manual. The connection diagram for the LN-8 can
be used for connecting the NA-3.
CONNECTION OF AN LN-742 TO THE
COMMANDER 500 CUMMINS
•
Shut the welder off.
•
Connect the LN-742 per instructions on the appro-
priate connection diagram in the DIAGRAMS sec-
tion.
•
Set the
“
WIRE FEEDER VOLTMETER
”
switch to
either
“
+
”
or
“
-
”
as required by the electrode being
used.
•
Set the
“
SELECTOR
”
switch to the
“
CV-WIRE
”
posi-
tion.
•
Adjust the
“
ARC CONTROL
”
knob to desired
Crispness. SOFT
for MIG and CRISP
for
INNERSHIELD.
•
Set the
“
WELDING TERMINALS
”
switch to the
“
REMOTELY CONTROLLED
”
position.
•
Set the
“
IDLE
”
switch to the
“
AUTO
”
position. When
not welding, the COMMANDER 500 CUMMINS
engine will be at the low idle speed.