beautypg.com

Installation – Lincoln Electric IM765 Commander 500 User Manual

Page 17

background image

A-9

INSTALLATION

COMMANDER 500 CUMMINS

A-9

CONNECTION OF AN LN-23P

WIRE

FEEDER TO THE COMMANDER 500 CUM-
MINS

Shut the welder off.

Connect the LN-23P per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion. (NOTE): When connecting an LN-23P to the
COMMANDER 500 CUMMINS, a K350-1 adapter kit
must be used.

Set the

WIRE FEEDER VOLTMETER

switch to

-

.

Set the

SELECTOR

switch to

CV-WIRE

position.

Set the

WELDING TERMINALS

switch to

REMOTELY CONTROLLED

.

Set the ARC CONTROL to desired crispness. SOFT

for MIG - CRISP for INNERSHIELD.

Set the

IDLE

switch to the

HIGH

position. If you

are using an LN-23P with the K350-1 adapter kit, the
electrode is not energized until the gun trigger is
closed.

CONNECTION OF AN NA-3 AUTOMATIC
WELDING SYSTEM TO THE COMMANDER
500 CUMMINS

For connection diagrams and instructions for connect-
ing an NA-3 Welding System to the COMMANDER 500
CUMMINS, refer to the NA-3 Welding System instruc-
tion manual. The connection diagram for the LN-8 can
be used for connecting the NA-3.

CONNECTION OF AN LN-742 TO THE
COMMANDER 500 CUMMINS

Shut the welder off.

Connect the LN-742 per instructions on the appro-

priate connection diagram in the DIAGRAMS sec-
tion.

Set the

WIRE FEEDER VOLTMETER

switch to

either

+

or

-

as required by the electrode being

used.

Set the

SELECTOR

switch to the

CV-WIRE

posi-

tion.

Adjust the

ARC CONTROL

knob to desired

Crispness. SOFT

for MIG and CRISP

for

INNERSHIELD.

Set the

WELDING TERMINALS

switch to the

REMOTELY CONTROLLED

position.

Set the

IDLE

switch to the

AUTO

position. When

not welding, the COMMANDER 500 CUMMINS
engine will be at the low idle speed.