Installation, Connection of lincoln electric wire feeders, Warning caution – Lincoln Electric IM765 Commander 500 User Manual

Page 16

background image

A-8

INSTALLATION

COMMANDER 500 CUMMINS

A-8

CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS

Shut off welder before making any electrical con-
nections.

------------------------------------------------------------------------

CONNECTION OF THE LN-25 TO THE
COMMANDER 500 CUMMINS

The LN-25 with or without an external contactor may
be used with the COMMANDER 500 CUMMINS. See
the appropriate connection diagram in the DIAGRAMS
section.

NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the COMMANDER 500 CUMMINS.

Shut the welder off.

For electrode Positive, connect the electrode cable

from the LN-25 to the

+

terminal of the welder and

work cable to the

-

terminal of the welder. For elec-

trode Negative, connect the electrode cable from the
LN-25 to the

-

terminal of the welder and work

cable to the

+

terminal of the welder.

Attach the single lead from the front of the LN-25 to

work using the spring clip at the end of the lead. This
is a sense lead to supply current to the wire feeder
motor; it does not carry welding current.

Set the SELECTOR switch to the

CV-WIRE

posi-

tion.

Set the

WELDING TERMINALS

switch to

WELD

TERMINALS ON

Adjust the

ARC CONTROL

knob to desired crisp-

ness. Generally, welding is best if the

ARC CON-

TROL

is set to SOFT for MIG and CRISP for

INNERSHIELD. You may however, want to start in
the middle and adjust (as needed) from there.

Set the

IDLE

switch to the

AUTO

position. When

not welding, the COMMANDER 500 CUMMINS
engine will be at the low idle speed. If you are using
an LN-25 with an internal contactor, the electrode is
not energized until the gun trigger is closed.

If you are using an LN-25 without an internal con-
tactor, the electrode will be energized when the
COMMANDER 500 CUMMINS is started.

------------------------------------------------------------------------

h. When the gun trigger is closed, the current sensing

circuit will cause the COMMANDER 500 CUMMINS
engine to go to the high idle speed, the wire will
begin to feed and the welding process started.
When welding is stopped, the engine will revert to
low idle speed after approximately 12 seconds
unless welding is resumed.

CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 500 CUMMINS

Shut the welder off.

Connect the LN-7 or LN-8 per instructions on the

appropriate connection diagram in the DIAGRAMS
section.

Set the

WIRE FEEDER VOLTMETER

switch to

either

+

or

-

as required by the electrode being

used.

Set the

SELECTOR

switch to the

CV-WIRE

posi-

tion.

Adjust the

ARC CONTROL

knob to desired

Crispness. SOFT

for MIG and CRISP

for

INNERSHIELD.

Set the

WELDING TERMINALS

switch to the

REMOTELY CONTROLLED

position.

Set the

IDLE

switch to the

HIGH

position. When

not welding, the COMMANDER 500 CUMMINS
engine will be at the low idle speed.

WARNING

CAUTION