INSTALLATION

COMMANDER 500

A-8

CONNECTION OF LINCOLN
ELECTRIC WIRE FEEDERS

Shut off welder before making any electrical connec-
tions.

------------------------------------------------------------------------

CONNECTION OF THE LN-25 TO THE
COMMANDER 500

The LN-25 with or without an external contactor may
be used with the Commander 500. See the appropri-
ate connection diagram in the DIAGRAMS section.

NOTE: The LN-25 (K431) Remote Control Module and
(K432) Remote Cable are not recommended for use
with the Commander 500.

a. Shut the welder off.

b. For electrode Positive, connect the electrode cable

from the LN-25 to the

+

terminal of the welder and

work cable to the

-

terminal of the welder. For

electrode Negative, connect the electrode cable
from the LN-25 to the

-

terminal of the welder and

work cable to the

+

terminal of the welder.

c. Attach the single lead from the front of the LN-25 to

work using the spring clip at the end of the lead.
This is a sense lead to supply current to the wire
feeder motor; it does not carry welding current.

d. Set the SELECTOR switch to the

WIRE WELD-

ING

position.

e. Set the

WELDING TERMINALS

switch to

WELD-

ING TERMINALS ALWAYS ON

f. Adjust the

ARC CONTROL

knob to desired crisp-

ness. Generally, welding is best if the

ARC CON-

TROL

is set to SOFT for MIG and CRISP for

Innershield.

g. Set the

IDLE

switch to the

AUTO

position. When

not welding, the Commander 500 engine will be at
the low idle speed. If you are using an LN-25 with
an internal contactor, the electrode is not energized
until the gun trigger is closed.

If you are using an LN-25 without an internal contactor,
the electrode will be energized when the Commander
500 is started.

------------------------------------------------------------------------

h. When the gun trigger is closed, the current sensing

circuit will cause the Commander 500 engine to go
to the high idle speed, the wire will begin to feed
and the welding process started. When welding is
stopped, the engine will revert to low idle speed
after approximately 12 seconds unless welding is
resumed.

CONNECTION OF LN-7 OR LN-8 TO THE
COMMANDER 500

a. Shut the welder off.

b. Connect the LN-7 or LN-8 per instructions on the

appropriate connection diagram in the DIAGRAMS
section.

c. Set the

LOCAL /REMOTE

switch to

REMOTE

for

the LN-8 or LN-7 with a K857 (or K857-1) remote
voltage control cable attached;

LOCAL

for LN-7

with no remote voltage control.

d. Set the

WIRE FEEDER VOLTMETER

switch to

either

+

or

-

as required by the electrode being

used.

e. Set the

SELECTOR

switch to the

WIRE WELD-

ING

position.

f. Adjust the

ARC CONTROL

knob to desired

Crispness.

SOFT for MIG and CRISP for

Innershield.

g. Set the

WELDING TERMINALS

switch to the

WELDING TERMINALS

REMOTELY CON-

TROLLED

position.

h. Set the

IDLE

switch to the

HIGH

position. When

not welding, the Commander 500 engine will be at
the low idle speed.

WARNING