Low Voltage and Line Voltage Wiring Instructions:

This product is to be installed in accordance with all electrical codes
and regulations. Please consult a qualified licensed electrician if you
are unable to understand any part of the instructions.


Low Voltage Instructions:

See Figure 4: Select the desired top or bottom opening in the
recessed media box and pull your low voltage cables through the
recessed media box opening. If you use keystone connectors,
connect your low voltage cables to the keystone connectors and
insert the keystone connectors into any standard size keystone
wall plate. Using two (2) of the four (4) supplied threaded screws,
install the standard size keystone wall plate inside of the recessed
media box. The standard size keystone plate mounting holes will
line up with the junction box tabs.





Line Voltage Instructions:

Warning: Turn off the power at your circuit breaker or fuse and
test the power to make sure it is off before wiring.

1. See Figure 5: Use a standard retrofit junction box (Allied Moulding

or Carlon). Select the top or bottom opening in the recessed media
box and install the retrofit junction box. Tighten the two mounting
screws on the retrofit junction box to secure the retrofit junction box
to the recessed media box.

2. Run the electrical wires to the retrofit junction box and install the

desired line voltage device (using line voltage device’s installation
instruction sheet) to support your application needs. Install a
standard size wall plate to cover your line voltage device.

3. Once all the line voltage wiring is complete and the standard size

wall plate is securely in place, turn power back on.

4. Use the provided black foam to seal any unused openings.



Finished Installation: See Figure 6



CAUTION

ƒ Never install low or line voltage wiring during lightning

storms.

ƒ Never install low or line voltage wiring in wet locations

unless the wire is specifically designed for wet locations.

ƒ Never touch un-insulated low or line voltage wires or

terminals unless the wire has been disconnected at its
source.

ƒ Use caution when installing low or line voltage cables.



IMPORTANT INSTRUCTIONS

ƒ Read and understand all instructions.
ƒ Follow all warning and instructions marked on the product.
ƒ Do not use this product near water, for example near a bath

tub, wash bowl, kitchen sink, or laundry tub, in a wet
basement, or near a swimming pool.

ƒ SAVE THESE INSTRUCTIONS.

5/18/09 Rev. 2

Figure 5

Figure 4

Figure 6