STI 9740 User Manual
STI Safety

INSTALLATION OF STI EXIT SIGN DAMAGE STOPPER STI-9640 AND STI-9740
All specifications and information shown were current as of publication and are subject to change without notice.
9640 MAY2005
Safety Technology International, Inc.
2306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Toll Free: 800-888-4784 • E-mail: [email protected]
Web: www.sti-usa.com
Safety Technology International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com
INSTALLATION INSTRUCTIONS
1. Center the wire guard over existing exit lamp.
2. Mark and drill (4) mounting holes (see pictorial for size).
Lag Bolts - If lag shields and lag bolts are used, make sure anchor is flush with
surface. Position guard, insert lag bolt and tighten. Length of bolt should be
selected to assure full thread engagement in anchor.
For installations that require tamperproof fasteners, order SUB81 stainless steel
screws and part no. 19038 bit.
Model
Width
Depth
STI-9640
13.75 in. (349 mm) 10.5 in. (267 mm)
2.75 in. (70 mm)
STI-9740
20.5 in. (520 mm)
15.5 in. (394 mm)
6.0 in. (152 mm)
Height
TOP VIEW
FRONT VIEW
DEPTH
WIDTH
HEIGHT
DRILL (4) .25 in.
(6.3mm) HOLES
19018 ANCHOR
(4) PROVIDED
19020 CLAMP
(4) PROVIDED
19033 SCREW
10 x 1.5 in.
(4) PROVIDED
EXISTING
EXIT SIGN
FRONT VIEW
TOP VIEW
Electronic warranty form at www.sti-usa.com/wc14