Cable Gland & Supply Cord Fitting Instructions (Single phase)
RG4000, RG6000, ES4000, ES6000
The cable gland assembly Fig. 7 (items 1 & 2) provides the necessary protection against
ingress of solid objects and moisture as well as providing cable retention.
Assembly instructions are as follows: -
1. Ensure selected cable sheath
diameter is within the permitted
range (6.5 to 9.5 mm).
2. Strip and prepare the cable
sheath and insulators as
shown in Fig. 5.
3. Disassemble cable gland as
shown in Fig. 7 and insert
cable into position
ensuring ‘O’-ring (item 1) is
placed over the cable before
the clamping insert (item 2) is tightened.
4. Consolidate the stranded conductor
ends by twisting and shape the earth
conductor as shown in Fig. 6 (item 3).
5. Remove earth terminal post clamping
components and assemble as shown
in Fig. 6 ensuring shaped conductor
is orientated as shown and all strands
of the conductor are clamped between
the
washers.
6. Insert and secure live and neutral
conductors ensuring all conductor
strands are clamped.
7. Confirm cable routing is as shown
in Fig. 7 and assemble and
secure terminal box lid.
L
N
E
110
70
8
12
70
8
3
2
1
(Dims. in mm)
Fig. 5
Fig. 6
Fig. 7