Wiring diagrams – Stuart Turner RG4000 User Manual
Page 12
- 12 -
Wiring Diagrams
The supply cord and internal wiring within the terminal box are routed and
secured to ensure compliance with the electrical standard EN 60335-1. It
is essential that any disturbance of this internal wiring is avoided and the
factory routing and securing of all internal wiring is always maintained.
MAIN WINDING
THERMO
TRIP
CAPACITOR
START WINDING
BROW
N
BLACK
BLUE
BROW
N
BL
UE
GREEN
YELLOW
L N E
LINK WIRE
(BLUE)
RG3300 / 4000 / 5000 / 6000
230V, 1phase, 50Hz SUPPLY
BROW
N
GREEN/YEL
LO
W
L N E
230 VAC/1PH/50/60Hz SUPPLY
WHITE
TERMINAL
BLOCK
CAP LINK
MAIN WINDIN
G
START WINDING
THERMO
TRIP
RED
BLAC
K
BR
OW
N
MA
IN
WINDIN
G
BL
UE
VI
OL
ET
GREEN/YELLOW
110 VAC/1PH/50/60Hz SUPPLY
TERMINAL
BLOCK
CAPACITOR
MA
IN
WINDIN
G
START WINDING
THERMO
TRIP
BLAC
K
MAIN
WINDIN
G
CAP LINK
BROW
N
BL
UE
RED
WHITE
VIOLET
BLUE
BLUE
BLUE
BROW
N
BLUE
RG5000 DUAL VOLTAGE MOTOR
L N E
CAPACITOR
ES4000 / 6000
Fig. 14
Fig. 15
Fig. 16