7 technical specification (twin models), Mechanical, Pump dimensions – Stuart Turner Techflo QT 50T User Manual
Page 15

- 15 -
Cont ...
7 TECHNICAL
SPECIFICATION (Twin Models)
Model
QT50
Twin
QT80
Twin
QT120
Twin
Electrical
Power supply
Volts/phase freqency
230/1/50
230/1/50
230/1/50
Enclosure
IPX4
IPX4
IPX4
Type of motor
Induction
Induction
Induction
Power consumption
340 Watts
540 Watts
820 Watts
Full load current
1.5 Amps
2.4 Amps
3.6 Amps
Rating
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Max. No Starts per hour
60
60
60
Mechanical
Max inlet head
8 metres
8 metres
8 metres
Max head (closed valve)
11 metres
22 metres
31 metres
Max working pressure*
270 kPa (2.7 bar)
370 kPa (3.7 bar)
480 kPa (4.8 bar)
Max ambient air temperature
40
o
C
40
o
C
40
o
C
Max water temperature**
65
o
C
65
o
C
65
o
C
Min water temperature
4
o
C
4
o
C
4
o
C
P
ump
Dimensions
Length
277 mm
334 mm
425 mm
Width
135 mm
135 mm
135 mm
Height (excluding flexible hoses)
220 mm
220 mm
220 mm
Gross Weight
5.8 Kg
7.0 Kg
9.7 Kg