7 technical specification (single models), Mechanical, Pump dimensions – Stuart Turner Techflo QT 50T User Manual
Page 14

- 14 -
Cont ...
Techflow reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note: For information on other voltages/frequencies which are not shown, consult any
supplementary instruction sheet supplied, or the rating label attached to the
pump.
*Note: Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
7.11
Noise: The equivalent continuous A-weighted sound pressure level at a distance
of 1 metre from the pump does not exceed 70 dB(A).
7 TECHNICAL
SPECIFICATION (Single Models)
Model
QT50 Single
QT80 Single
QT120 Single
Electrical
Power supply
Volts/phase freqency
230/1/50
230/1/50
230/1/50
Enclosure
IPX4
IPX4
IPX4
Type of motor
Induction
Induction
Induction
Power consumption
220 Watts
300 Watts
450 Watts
Full load current
1.0 Amps
1.3 Amps
1.9 Amps
Rating
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Intermittent, 30 mins on,
30 mins off
Max. No Starts per hour
60
60
60
Mechanical
Max inlet head
8 metres
8 metres
8 metres
Max head (closed valve)
11 metres
22 metres
31 metres
Max working pressure*
270 kPa (2.7 bar)
370 kPa (3.7 bar)
480 kPa (4.8 bar)
Max ambient air temperature
40
o
C
40
o
C
40
o
C
Max water temperature
65
o
C
65
o
C
65
o
C
Min water temperature
4
o
C
4
o
C
4
o
C
P
ump
Dimensions
Length
277 mm
300 mm
334 mm
Width
135 mm
135 mm
135 mm
Height (excluding flexible hoses)
220 mm
220 mm
220 mm
Gross Weight
5.3 Kg
5.7 Kg
6.6 Kg