Product description motor, Pump, Limits of application – Stuart Turner Self Priming Jet 90 Centrifugal User Manual
Page 3: Technical specification
- 3 -
PRODUCT DESCRIPTION
Motor
Induction type, totally enclosed fan ventilated cooling, continuously rated, class ‘B’
insulation, permanent capacitor, IP 44 enclosure. Motors are fitted with an integral auto-
resetting thermal overload, comply with IEC 34-1 and are suitable for a supply of 230V,
1 phase, 50Hz.
Pump
Close coupled, single stage, end suction configuration and of centrifugal design with
integral Jet injector.
Standard pump materials of construction of major wetted parts are as follows:-
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note: For information on other voltages/frequencies which are not shown, consult any
supplementary instruction sheet supplied, or the rating label attached to the
pump.
LIMITS OF APPLICATION
*Note:
Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
TECHNICAL SPECIFICATION
Model
Body
Impeller
Shaft
Injector
Diffuser
Mechanical Seal
All
Polypropylene
Noryl
Stainless Steel
Noryl
Noryl
Nitrile/carbon
Ceramic/Stainless Steel
Model
Max.
Water Temp
(°C)
Min.
Water Temp
(°C)
Max.
Ambient
Air Temp
(°C)
Max.
Suction
Lift (m)
Max. Head
(Pump Closed
Valve) (m)
Max. Viscosity
*Max.
Working
Pressure
kPa (bar)
Max.
Inlet
Head
(m)
Max. No
Starts/h
(Redwood
No. 1 Scale)
Centistokes
40
35
4
40
7
36.5
50
9.5
600 (6)
5
30
90
35
4
40
7
51
50
9.5
600 (6)
5
30
Model
Supply
Max. Watts
Consumed
Nominal
Watts
Output
(Motor)
Full
Load
Current
(AMPS)
Enc.
Rating
Duty Rating
Dims. (mm)
Gross
Weight
(packed)
Kg
No of
Pump
Stages
L
W
H
40
230/1/50
490
340
2.4
IP44
Continuous
358
209
225
7.2
1
90
230/1/50
1200
840
5.2
IP44
Continuous
400
230
230
12.4
1
Cont....